Master's Dissertation
DOI
https://doi.org/10.11606/D.43.2014.tde-02022015-133946
Document
Author
Full name
Alejandro Heyner Lopez Gonzales
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Costa, Paulo Roberto (President)
Nogueira, Maria do Socorro
Rizzutto, Marcia de Almeida
Title in Portuguese
Estudo experimental das relações entre kerma no ar e equivalente de dose ambiente em barreiras secundárias de salas radiológicas
Keywords in Portuguese
Espalhamento
Física médica
Radiação ionizante
Radioproteção
Raios X
Abstract in Portuguese
No Brasil, para fins de planejamento de barreiras físicas em instalações radiográficas ou para a verificação dos níveis de restrição de dose em levantamentos radiométricos, deve ser usada a grandeza operacional equivalente de dose ambiente. Na prática, os monitores de radiação utilizados em proteção radiológica apresentam suas leituras na grandeza dosimétrica kerma no ar. Portanto, é preciso utilizar um coeficiente que converta esta grandeza dosimétrica na grandeza operacional recomendada. As normas nacionais estabelecem que o coeficiente de conversão no valor de 1,14 Sv/Gy deve ser usado para realizar esta operação, desconsiderando a diferença na distribuição espectral dos fótons dos feixes de raios X comumente encontrados em salas de radiologia convencional. O presente trabalho tem por objetivo determinar os coeficientes de conversão considerando a distribuição espectral da radiação secundária e secundária transmitida através de placas de argamassa baritada. Para atingir os objetivos propostos, foi desenvolvida uma metodologia experimental para as medições dos espectros das radiações secundárias e secundárias transmitidas usando um sistema espectroscópico com detector de CdTe e uma câmara de ionização de 1800 cm3. A região torácica de um objeto simulador antropomórfico, RANDO® Man, foi usada como região espalhadora. Foram utilizadas tensões no tubo entre 40 kV e 150 kV com intervalos na tensão de 10 kV. Os ângulos de espalhamento foram de 30°, 60°, 90° 120° e 150° em relação ao eixo do feixe primário. Como atenuador da radiação secundária foram utilizadas placas de argamassa baritada com espessuras de aproximadamente 10, 15, 20 e 25 mm. Os resultados mostram que, para a radiação secundária, os coeficientes de conversão são maiores que o valor estabelecido no Brasil. Num exemplo típico de levantamento radiométrico, a estimativa do equivalente de dose ambiente determinado usando o coeficiente de conversão calculado a partir dos espectros resultou em um valor cerca de 40 % superior ao equivalente de dose ambiente calculado a partir do coeficiente adotado pela norma nacional.
Title in English
Experimental study of the conversion coefficient from Air Kerma to Ambient Dose Equivalent for secondary barriers in diagnostic radiological facilities
Keywords in English
Ionizing Radiation
Medical Physics
Radiation Portection
Scattering
X-ray
Abstract in English
In Brazil, for planning purposes of the physical barriers in a radiographic installation and for levels verification of dose restriction in radiometric surveys, the ambient dose equivalent operational quantity should be used. In practice, radiation monitors used in radiation protection, are calibrated in dosimetry quantity air kerma. Therefore, it is important to use a conversion coefficient, which turns this dosimetric quantity into a recommended operational quantity. The rules followed in Brazil still establish that the value of the conversion coefficient, 1.14 Sv/Gy, must be used in area monitoring, disregarding differences between the beam types with different photon spectral distribution, commonly found in conventional radiology rooms. Consequently, this work aims to determine the conversion coefficients considering the spectral distribution of the secondary radiation and secondary-transmitted radiation through barium mortar plates. To achieve the proposed objectives, it has been developed an experimental method for measurement of secondary and secondary transmitted spectra using a spectroscopic system with CdTe detector and an ionization chamber 1800 cm3. The thoracic region of an anthropomorphic phantom, RANDO® Man, was used as a scatter region. The voltages used began 40 kV up to 150 kV in displacements of 10 kV, the scattering angles were 30°, 60°, 90° 120° and 150° with respect to the axis of the primary beam. As attenuator object of the secondary radiation was used barium mortar plates with thicknesses of 10, 15, 20 and 25 mm approximately. The results show that for the secondary radiation, the conversion coefficients are greater than the value set in Brazil. In a typical example of radiometric survey, the estimated ambient dose equivalent using the conversion coefficient calculated from the spectra, is a 40% higher compared to the value obtained using the coefficient recommended in Brazil.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-03-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.