Master's Dissertation
DOI
https://doi.org/10.11606/D.43.2006.tde-29032007-143448
Document
Author
Full name
Tiago Fiorini da Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Martins, Marcos Nogueira (President)
Added, Nemitala
Sciani, Valdir
Title in Portuguese
"Início de operação e caracterização do sistema injetor do Mícrotron do IFUSP"
Keywords in Portuguese
Aceleração de Partículas
Física Nuclear
Óptica eletrônica
Abstract in Portuguese
Neste trabalho apresentamos o início de operação do sistema injetor do Mícrotron do IFUSP. São apresentados estudos inéditos do tratamento de desalinhamentos tanto de uma única lente quanto de um conjunto delas. As lentes magnéticas deste estágio foram alinhadas com precisão melhor que 0,18 mm. Estabelecemos um sistema de aquisição de imagens do feixe e com ele fizemos medidas da emitância, cujo valor foi determinado em (2,32 ± 0,05) pi.mm.mrad, independentemente da tensão de aceleração no canhão de elétrons, devido à limitação imposta pelo colimador da entrada do chopper.
Title in English
Commissioning of the injector system of the IFUSP Microtron
Keywords in English
Beam Optics
Nuclear Physics
Particle Acceleration
Abstract in English
In this work we present the commissioning of the IFUSP Microtron injector system. We developed a new method to treat misalignments on a single lens as well as in a group of them. We installed an image acquisition system to acquire beam images from the fluorescent screen monitor. Emittance was measured and found to be (2,32 ± 0,05) pi.mm.mrad, independently of the beam energy, showing the limitation imposed by the collimator placed at the entrance of the chopper cavity.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Disserta.pdf (4.86 Mbytes)
Publishing Date
2007-04-09
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • SILVA, T.F., and MARTINS, M.N.. Statistical treatment of misalignments in particle accelerators [doi:10.1016/j.cpc.2010.11.026]. Computer Physics Communications [online], 2011, vol. 182, n. 3, p. 679-682.
All rights of the thesis/dissertation are from the authors