Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2000.tde-12112007-145103
Documento
Autor
Nombre completo
Carlos Antonio Neves
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2000
Director
Tribunal
Lago, Claudimir Lúcio do (Presidente)
Petri, Denise Freitas Siqueira
Rohwedder, Jarbas José Rodrigues
Título en portugués
Dispositivos para cristais piezelétricos de quartzo com eletrodos separados para estudos de processos físicos e químicos de superfícies e filmes depositados
Palabras clave en portugués
Análise de impedância
Cristal pizelétrico de quartzo de eletrodos separados
ESPC
PQC
Química analítica
Silanização
Resumen en portugués
Este trabalho descreve o desenvolvimento de dispositivos usando cristais piezelétricos de quartzo com eletrodos separados (ESPC) que, através do monitoramento da freqüência de oscilação e do espectro de impedância, permitem estudar modificações superficiais do cristal. Para o monitoramento de freqüência de oscilação, usou-se um circuito oscilador TTL seguido por um freqüencímetro e por uma interface conectada a um microcomputador. Para o controle desta interface, foi desenvolvida uma biblioteca de ligação dinâmica e um programa em HP-VEE 4.0. Os espectros de impedância foram obtidos via programas que controlam um analisador de impedâncias via protocolo GPIB. O primeiro dispositivo presta-se a estudos de filmes depositados (DFD) e é feito em acrílico com eletrodos em latão posicionados a décimos de milímetros do cristal. Sua parte superior possui uma camisa de água para a termostatização. O segundo, semelhante ao primeiro, permite a modificação de superfície (DMS) de ESPC através da introdução de reagentes na fase gasosa. Os dois dispositivos foram caracterizados e o primeiro mostrou boa linearidade entre as massas depositadas e aquelas estimadas pela equação de Sauerbrey. O DFD foi utilizado para monitoramento em tempo não real da modificação superficial do cristal por N-[3-(trimetoxisilil)propil]-1,2-etanodiamina seguida por reação com ácido iodoacético. Os resultados mostraram evidências de aumento de massa e mudança nas propriedades viscoelásticas do filme. O DMS foi utilizado para monitoramento em tempo real da modificação superficial com trimetilclorosilano (TMCS) e dimetildiclorosilano (DMDCS). Com o TMCS, devido à formação de uma monocamada, não foi possível monitorar variações significativas de freqüência de oscilação. Com o DMDCS foi possível verificar a formação de poli(dimetilsiloxano).
Título en inglés
Separated electrodes piezelectric quartz crystal devices for studies ogf physical and chemical process and film coated
Palabras clave en inglés
Analytical chemistry
Electrodes separated piezelectric quartz crystal
ESPC
Impedance analysis
PQC
Sinalization
Resumen en inglés
This dissertation describes the development of devices based on separated-electrode piezoelectric quartz crystals (ESPC) to study surface modifications. This is accomplished by monitoring the oscillation frequency and impedance spectrum of the crystal in the cell. A TTL oscillator coupled to a frequency counter and a microcomputer interface is used for monitoring the oscillation frequency. A dynamic link library and HP-VEE 4.0 programs were developed to control the interface. Other programs were also developed to acquire the impedance spectra from a spectrum analyzer by using the GPIB protocol. The first device (DFD) is intended to study deposited films. It is made in Plexiglas, with brass electrodes positioned at a few tenths of millimeters from the crystal surface, and a thermostatic water jacket. The second device (DMS) is similar to the first one, but allows the use of corrosive reagents in the gas phase for surface modification. The performance of both devices was evaluated and the results showed good agreement between the deposited mass and the one predicted by Sauerbrey equation. The DFD was used for offline monitoring of the crystal surface modification by N-[3-(triethoxysilyl)propyl]-1,2-ethanediamine followed by iodoacetic acid. The results show evidences of mass and viscoelastic variations of the film. The DMS was used for on-line monitoring during surface modification with trimethylchlorosilane (TMCS) and dimethyldichlorosilane (DMDCS). Due to the monolayer formed by TMCS, no significant frequency variation could be observed. On the other hand, the polymerization of DMDCS could be monitored.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-11-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.