Doctoral Thesis
DOI
https://doi.org/10.11606/T.46.2007.tde-14082007-111340
Document
Author
Full name
Denise Lowinsohn
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Bertotti, Mauro (President)
Fatibello Filho, Orlando
Gutz, Ivano Gebhardt Rolf
Richter, Eduardo Mathias
Serrano, Silvia Helena Pires
Title in Portuguese
Desenvolvimento de um sensor para análise de lactato em amostras alimentares e biológicas
Keywords in Portuguese
Biossensor
Enzima
Fia
Lactato
Lactato oxidase
Abstract in Portuguese
Neste trabalho são apresentados resultados relacionados a estudos sobre o comportamento eletroquímico do lactato e do peróxido de hidrogênio em diversos eletrodos em meio de diferentes pHs utilizando voltametria cíclica. Também foi investigado o comportamento eletroquímico do peróxido de hidrogênio em eletrodos modificados com filmes de hexacianoferratos utilizando eletrodos de platina e carbono vítreo. A vantagem do uso do CTAB na modificação da superfície de carbono vítreo com Azul da Prússia foi confirmada no que se refere à melhora da sensibilidade e da estabilidade das medidas. Numa etapa posterior desenvolveu-se um biossensor para a determinação de lactato pelo monitoramento de peróxido de hidrogênio produzido na reação catalisada de lactato com oxigênio na presença da enzima lactato oxidase. Nessa etapa, o trabalho consistiu em imobilizar a enzima lactato oxidase na superfície do eletrodo, previamente, modificado com Azul da Prússia, com o auxílio de Nafion®. Após a construção do biossensor e a otimização das condições de análise (pH, quantidade de enzima, volume da amostra e vazão) para obtenção de maior sinal analítico no desenvolvimento do método para a determinação de lactato por análise em fluxo, averiguou-se a repetibilidade das medidas (Clactato = 0,28 mmol L-1) obtendo-se um desvio padrão de 2,2% para 18 repetições. A freqüência analítica foi estimada em 160 injeções por hora com limite de detecção de 0,84 µmol L-1 e linearidade até 0,28 mmol L-1 de lactato. O biossensor foi aplicado na quantificação de lactato em amostras alimentares (cervejas alcoólicas e não alcoólicas) e biológicas (sangue liofilizado e recém coletado). Por fim, realizaram-se estudos envolvendo a variação da concentração de lactato sanguíneo em função da intensidade de atividade esportiva. Os resultados obtidos pelo método proposto foram comparados com aqueles oriundos do uso de método de referência.
Title in English
Fabrication of a biosensor for determination of lactate in food and blood samples
Keywords in English
Biosensor
Enzyme
Fia
Lactate
Lactate oxidase
Abstract in English
Results on the investigation of the electrochemical behavior of lactate and hydrogen peroxide at various electrodic surfaces at different pHs using cyclic voltammetry are presented. Experiments were also carried out with platinum and glassy carbon electrodes modified with hexacyanoferrate films. The advantage of using CTAB in the electrodeposition step of Prussian Blue films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of measurements. The immobilization of lactate oxidase onto glassy carbon electrodes modified with a Prussian Blue layer using Nafion® was performed to fabricate a biosensor for lactate. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 mmol L-1 lactate with a limit of detection of 0.84 µmol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The analytical frequency was calculated as 160 injections h-1. The usefulness of the method was demonstrated by determining lactate in beer (alcoholic and nonalcoholic beers) and blood samples (lyophilized and freshly collected). Finally, the influence of physical exercise on the blood lactate level was studied. Results obtained by using the proposed amperometric detector compared well with the reference method.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
LDENISETESE.pdf (1.22 Mbytes)
Publishing Date
2007-09-12
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI