Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.46.2019.tde-15022019-113640
Document
Auteur
Nom complet
Ruben Gregorio Moreno Moreno
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2001
Directeur
Jury
Oliveira, Elisabeth de (Président)
Cadore, Solange
Gutz, Ivano Gebhardt Rolf
Titre en portugais
Determinação de mercúrio em amostras ambientais por espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite com superfície modificada
Mots-clés en portugais
Atomic absorption spectrometry
CVAAS
Paládio
Permanent modifier
Química ambiental
Química analítica instrumental
Química analítica qualitativa
Resumé en portugais
Um procedimento eletroquímico para deposição de paládio no interior de um tubo de grafite para modificação química permanente e um sistema de geração de vapor frio para a determinação de níveis traços de mercúrio em água e sedimento através de espectrometria de absorção atômica é proposto. A célula eletroquímica tubular para as deposições de paládio em fluxo foi construída aproveitando a estrutura original do tubo de grafite o qual opera como eletrodo de trabalho. Um tubo de aço inoxidável, posicionado na saída da célula, é usado como o eletrodo auxiliar. O valor do potencial aplicado no eletrodo de grafite é medido contra um micro eletrodo de referência de Ag/AgCl inserido sobre o eletrodo auxiliar. Soluções de paládio em tampão de acetato (100 milimol L-1, pH=4,70), numa vazão de 0,5 mL min-1 foram usados para executar a deposição eletroquímica durante o intervalo de tempo de 60 min. O sistema de geração de vapor frio consiste de um micro-reator de polietileno e frasco separador líquido-gás, volume total de 4,0 ml, que é descartado depois de cada amostragem para evitar inter-contaminação das amostras. Volumes de 1,0 ml de reagente (2,0% m/v NaBH4 em 0,10 mol L-1 de NaOH) e 1,0 ml de soluções analíticas ou amostras em 0,25 mol L-1 de HNO3 são levados para o reator e separador líquido-gás usando uma bomba peristáltica. O vapor de mercúrio é transportado ao tubo de grafite modificado eletroquimicamente com fluxo de argônio de 212 ml min-1 e pré-concentrado durante 120 s. O limite de detecção obtido foi 93 ng L-1 (n=20, 3δ). O desempenho deste sistema foi testado para determinação de mercúrio em água potável, água não potável e sedimentos de lagoa. A confiança de todo procedimento foi confirmada através de testes de recuperação.
Titre en anglais
Determination of mercury in environmental samples by atomic absorption spectrometry with electrothermal atomization in graphite furnace with modified surface
Mots-clés en anglais
Atomic absorption spectrometry
CVAAS
Environmental chemistry
Instrumental analytical chemistry
Palladium
Permanent modifier
Qualitative analytical chemistry
Resumé en anglais
An electrochemical procedure for palladium deposition on the inner of a graphite tube for permanent chemical modification and a cold vapor generation system for the determination of trace levels of mercury in water and sediment by atomic absorption spectrometry are proposed. The tubular electrochemical cell for the deposition of palladium was assembled on the original geometry of a graphite tube that operates as the working electrode. A stainless steel tube, positioned downstream from the working electrode, is used as the auxiliary electrode. The potential value applied on the graphite electrode is measured against a micro reference electrode (Ag/AgCl) inserted into the auxiliary electrode. Palladium solutions in acetate buffer (100 milimol L-1, pH=4.70), flowing at 0.5 mL min-1 for 60 min was used to perform the electrochemical deposition. A cold vapor generation system consist of a micro polyethylene reactor and gas-liquid separator flask, total volume of 4.0 mL, that is discarded after each sampling to avoid intercontamination of the samples. Volumes of 1.0 mL of reagent (2.0% m/v NaBH4 in 0.10 mol L-1 of NaOH) and 1.0 mL of reference or sample solutions in 0.25 mol L-1 of HNO3 are carried out to the reactor and gas-liquid separator by using a peristaltic pump. The mercury vapor is transported to the graphite tube electrochemically modified with argon flow (200 mL min-1) and pre-concentrated during 120 s. The detection limit obtained was 93 ng L-1 (n=20, 3δ). The performance of these system was tested for determination of mercury in potable and non-potable water and lake sediments. The reliability of the entire procedure was confirmed by recovery tests.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2019-02-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.