Detecção piezelétrica não-gravimétrica de boro empregando cristal de quartzo com eletrodo separado e superfície quimicamente modificada
Mots-clés en portugais
Análise por injeção em fluxo
Boro
Cristais piezelétricos de quartzo
Modificação química de superfície
Sensores
Resumé en portugais
Cristais piezelétricos de quartzo (PQC's) com configuração de eletrodo separado e superfície quimicamente modificada foram utilizados para obtenção de um sensor para boro. Uma cela de detecção foi construída, de maneira que um eletrodo de aço inoxidável era mantido a uma pequena distância (0,3 mm) da superfície do PQC, da qual foi removido o eletrodo de ouro original. Foi verificado,por espectroscopia de impedância, medidas de freqüência de oscilação e simulações de espectros de impedância do circuito equivalente da cela, que as propriedades físico-químicas (condutividade, permissividade, densidade e viscosidade) das soluções influenciam de modo diferenciado as freqüências características da cela (ressonância e oscilação). Com o intuito de tomar a superfície sem eletrodo do PQC seletiva a boro, foram experimentadas várias estratégias de modificação química, as quais tinham por objetivo imobilizar polióis (manitol e N-metilglucamina) através de reações de silanização ou deposição de polímeros modificados. Os melhores resultados foram obtidos com o recobrimento do PQC com um filme fino (0,1 a 0,5 µm) de um polímero resultante da modificação da poliepicloridrina com N-metilglucamina (NG). O sensor para boro foi avaliado em um sistema de análises por injeção em fluxo (FIA), em que a solução transportadora era uma solução de etilenodiaminotetraacetato disódico (EDTA) 50 mmol/L (pH 8,5). Observou-se que o mecanismo de resposta desse sensor era predominantemente não-gravimétrico, devido a um aumento de rigidez do filme de recobrimento, causado pela complexação do boro pelos grupos NG ancorados ao polímero. Além disso, o sensor apresenta uma característica bastante interessante que é a retenção do boro, o que possibilita uma diminuição do limite de detecção (LD) em FIA, por meio do aumento do volume de amostra injetado. Para remover o boro do filme sensor, era injetada uma solução de manitol 1 mol/L. Para volumes injetados de 160 e 1000 µL de solução de borato foram alcançados LD's de 2 e 0,3 /-lmol/L, respectivamente. É possível detectar até 3 ng do analito presentes no volume de amostra injetado. O efeito de vários prováveis íons interferentes (Mg 2+, Ca2+, Al3+, Cr3+, Mn2+, Fé3+, Co2+, Cu2+, Ni2+, Zn2+, Sn2+, Pb2+, HPO42-, SiO32-, F-, Cl-, SO42-, NO3-, CH3COO-, CO32-, VO3-, Sb(OH)6- AsO4-, AsO3-, SeO3-, SeO4- e Ge(OH) 62-)foram avaliados, porém apenas o íon germanato apresentou significativa interferência, tanto que o sensor também foi considerado adequado para a determinação dessa espécie. A adição de sulfeto à amostra eliminou completamente a interferência do germânio. A não interferência dos íons metálicos é devida à complexação dos mesmos por EDTA presente na solução transportadora. Foi constatado que a presença de polióis, em alta concentração, na amostra afeta a resposta do sensor, uma vez que esses compostos competem com o filme sensor pelo analito. Os resultados obtidos com o sensor encorajaram a construção de um equipamento automatizado de FIA, o qual foi empregado com sucesso na determinação de boro em amostras de águas minerais, sucos de uva, vinagre, vinho e amostra certificada de água de rio.
Titre en anglais
Non-gravimetric piezoelectric detection of boron by using quartz crystal with electrode separated and chemically modified surface
Mots-clés en anglais
Boron
Chemical surface modification
Flow injection analysis
Piezoelectric quartz crystal
Sensors
Resumé en anglais
Piezoelectric quartz crystals (PQC's) with electrode-separated configuration and chemically modified surface were used to develop a boron sensor. A detection cell was built in such a way that a stainless-steel electrode was held at a short distance (0.3 mm) from the PQC surface, whose original gold electrode was removed. By using impedance spectroscopy, oscillation frequency measurements, and simulations of impedance spectra of the cell equivalent circuit, it was observed that the physico-chemical properties (conductivity, permissivity, density and viscosity) of the solution affect in different ways the characteristic frequencies of the cell (resonance and oscillation). In order to make the electrodeless PQC surface selective to boron, several chemical modification strategies were tested with the aim of anchoring poliols (manitol and N-metilglucamine) via silanization reactions or deposition of modified polymers. Best results were obtained with PQC coated with a thin film (0.1 to 0.5 µm) of a polymer, which was the product of the polyepichlorohydrin modification with N-methylglucamine (NG). The sensor was evaluated in a flow injection analysis system (FIA), which used a carrier solution containing disodic ethylenediaminetetraacetate (EDTA) 50 mmol/L (pH 8.5). It was observed that the mechanism of detection of this sensor is predominantly nongravimetric, owing to an increase in the stiffness of the covering film, because of the complex formation involving boron and the NG groups, which were incorporated in the polymer. Moreover, the sensor shows an interesting characteristic that is the boron retention, which allows decreasing the limit of detection (LOD) of the FIA method by increasing the injected sample volume. Boron is eluted from the sensor film with 1 mol/L manitol solution. For 160 and 1000 µL volumes of borate solution, the LOD's were 2 and 0.3 µmol/L, respectively. It is possible to detect down to 3 ng of boron in the injected sample volume. The effect of several ions (Mg 2+, Ca2+, Al3+, Cr3+, Mn2+, Fé3+, Co2+, Cu2+, Ni2+, Zn2+, Sn2+, Pb2+, HPO42-, SiO32-, F-, Cl-, SO42-, NO3-, CH3COO-, CO32-, VO3-, Sb(OH)6-' AsO4-, AsO3-, SeO3-, SeO4- e Ge(OH) 62-) was evaluated. Only the germanate ion showed a significant interference, thus, the sensor can also be suitable for this species. However, this interference can be eliminated by the addition of sulfide to the sample. The non-interference of the metal ions is due to the complex formation with EDTA present in the carrier solution. Polyols at high concentration in the samples affect the sensor response, because these compounds compete with the sensor film for the analyte. An automated FIA equipment was built and successfully applied for determination of boron in samples such as mineral water, grape juice, vinegar, wine, and a standard reference material (river water).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-06-01
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.