• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.46.2023.tde-22112023-162845
Document
Auteur
Nom complet
Gabriel Lorencil de Almeida Serafim
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2023
Directeur
Jury
Nomura, Cassiana Seimi (Président)
Intima, Danielle Polidorio
Naozuka, Juliana
Titre en portugais
Avaliação da potencialidade da espectrometria de emissão óptica com plasma induzido por laser na análise de material geológico
Mots-clés en portugais
Espectrometria de emissão óptica com plasma induzido por laser
LIBS
Material geológico
Nióbio
Zircônio
Resumé en portugais
Devido às características refratárias das amostras com elevado teor de silicatos como rochas e escórias, a sua dissolução requer o uso de ácidos concentrados, alta pressão e temperatura. Nessa situação, o uso de uma técnica que possibilita análise direta dessas amostras se mostra como uma ótima alternativa. A espectrometria de emissão óptica com plasma induzido por laser (LIBS) vem se tornando uma técnica muito atrativa e bastante explorada na análise química por possibilitar a análise de amostras sólidas dispensando a conversão delas em solução. Apesar disso, a análise quantitativa ainda é considerada o calcanhar de Aquiles da técnica, devido à complexidade dos processos de interação entre o laser e as amostras que causam efeitos de matriz indesejados. Assim o trabalho propõe investigar diferentes formas de técnicas de calibração para possibilitar a análise quantitativa de Zircônio e Nióbio por LIBS, para tal foi utilizado como técnica de preparo de amostra a diluição em pastilha fundida, também foi realizado uma otimização instrumental comparando a relação do sinal com razão entre a área integrada do sinal de emissão com o sinal de fundo (SBR). Após a otimização foi determinado que a melhor condição instrumental seria de diâmetro de focalização de 85µm, energia de pulso 20mJ, tempo de atraso de 0,1 µs e o número de pulsos igual a 660 para ambos os analitos. Foram testados métodos de calibração externa e calibração por adição de padrão, assim como o uso de padrão interno, sendo a calibração externa com uso de padrão interno a técnica que melhor demonstrou resultados para determinação de ambos os elementos com uma taxa e recuperação de 100% e 102% para o Nióbio e o Zircônio respectivamente.
Titre en anglais
Evaluation of potentiality of laser-induced breakdown spectrometry on geological material analysis 2022
Mots-clés en anglais
Geological material
Laser-induced breakdown spectroscopy
Niobium
Zirconium
Resumé en anglais
Due to the refractory characteristics of samples with a high content of silicates such as rocks and slag, their dissolution requires the use of concentrated acids, high pressure and temperature. In this situation, the use of a technique that allows direct analysis of these samples proves to be a great alternative. Laser-induced plasma optical emission spectrometry (LIBS) has become a very attractive and widely explored technique in chemical analysis because it enables the analysis of solid samples without the need to convert them into solution. Despite this, quantitative analysis is still considered the Achilles heel of the technique, due to the complexity of the interaction processes between the laser and the samples that cause unwanted matrix effects. Thus, the work proposes to investigate different forms of calibration techniques to enable the quantitative analysis of Zirconium and Niobium by LIBS, for this purpose dilution in molten tablet was used as a sample preparation technique, an instrumental optimization was also performed comparing the signal ratio ratio between the integrated area of the emission signal and the background signal (SBR). After optimization, it was determined that the best instrumental condition would be a focusing diameter of 85µm, pulse energy of 20mJ, delay time of 0.1µs and the number of pulses equal to 660 for both analytes. External calibration and standard addition calibration methods were tested, as well as the use of an internal standard, with external calibration using an internal standard being the technique that best demonstrated results for the determination of both elements with a rate and recovery of 100% and 102% for Niobium and Zirconium respectively.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2024-01-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.