Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2011.tde-05052011-143818
Document
Author
Full name
Marco Kawamura Demange
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Camanho, Gilberto Luis (President)
Andrade, Marco Antonio Percope de
Barretto, João Mauricio
Cohen, Moises
Hernandez, Arnaldo Jose
Title in Portuguese
Comparação entre o planejamento pré-operatório e a navegação intraoperatória na osteotomia valgizante da tíbia: análise do eixo mecânico e do tamanho das cunhas de adição
Keywords in Portuguese
Joelho
Navegação cirúrgica
Osteotomia
Tíbia
Abstract in Portuguese
O resultado clínico a longo prazo das osteotomias valgizantes da tíbia depende da obtenção do adequado alinhamento do eixo mecânico pelo procedimento cirúrgico. Essa correção do eixo mecânico é obtida pela adição ou subtração de cunhas ósseas. O tamanho das cunhas pode ser planejado pré-operatoriamente ou determinado durante a cirurgia utilizando controle intraoperatório do alinhamento do membro. Modernamente, o controle intraoperatório pode ser realizado com auxílio de equipamentos de navegação cirúrgica computadorizados. Neste estudo, comparamos os valores dos eixos mecânicos e dos tamanhos das cunhas obtidos pelo método de planejamento pré-operatório das osteotomias com cálculo trigonométrico e pelas cirurgias auxiliadas por sistema de navegação intraoperatória. A medida dos eixos mecânicos em imagens radiográficas panorâmicas dos membros inferiores foi realizada por catorze cirurgiões de joelho em treze pacientes. A cirurgia de osteotomia valgizante auxilada por navegação cirúrgica foi realizada pelo mesmo cirurgião nos mesmos treze pacientes, documentando-se o tamanho da cunha de adição medial e os eixos mecânicos do membro inferior. Após as cirurgias, planejamos os tamanhos das cunhas de adição medial, por cálculo trigonométrico, utilizando os dados dos eixos mecânicos medidos nas radiografias. Nós realizamos comparação entre os valores dos eixos mecânicos obtidos nas cirurgias e os valores medidos nas imagens radiográficas e entre os tamanhos das cunhas de adição medial medidos intraoperatoriamente e planejadas nos cálculos trigonométricos. A análise dos dados foi realizada por análise descritiva dos resultados e por gráficos de Bland e Altman. Como resultados, observamos alta correlação entre os valores dos eixos mecânicos medidos nos exames radiográficos e pelo navegador cirúrgico e observamos que os valores planejados para as cunhas de adição são diferentes dos valores medidos durante as cirurgias
Title in English
Comparison of preoperative planning and intraoperative navigation surgery in tibial osteotomies: analysis of the mechanical axis and the size of the wedges of addition
Keywords in English
Computed navigation
Knee
Osteotomy
Tibia
Abstract in English
The long-term clinical outcome of tibial osteotomy depends on achieving the proper mechanical axis alignment for the surgery. Adding or subtracting bone wedges obtains the mechanical axis correction. The correction size may be planned preoperatively or defined during surgery under limb alignment control. Nowadays, the limb alignment control may be accomplished with the aid of computerized surgical navigation equipment. In this study, we compared the values of the mechanical axes and the wedges sizes obtained by the osteotomies preoperative planning method with trigonometric calculation and those values measured on navigated surgeries. Fourteen knee surgeons performed the measurement of the mechanical axes in panoramic radiographs of the lower limbs of thirteen patients. The same surgeon performed all thirteen surgeries. The wedges sizes and the mechanical axes of the lower limb were measured during surgeries. After surgery, the sizes of the planned addition of medial wedges, for trigonometric calculation, using data from the mechanical axis measured on the radiographs. We carry out comparison between the values of the mechanical axes obtained in the surgeries and the values measured in the radiographs and between the sizes of the wedges and wedge sizes planned in trigonometric calculations. We performed data analyses by descriptive analysis and Bland and Altman. We have observed a high correlation between the values of the mechanical axes measured on radiographs and in navigated surgeries and noticed that the planned values for wedges are different from values measured during surgery
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-05-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.