Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2009.tde-16042009-130758
Document
Author
Full name
Fabio Janson Angelini
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Albuquerque, Roberto Freire da Mota e (President)
Carneiro Filho, Mario
Luzo, Marcus Vinicius Malheiros
Title in Portuguese
Estudo comparativo, em cadáveres, da determinação dos pontos isométricos para a reconstrução do ligamento cruzado anterior do joelho com e sem navegação
Keywords in Portuguese
Artroscopia
Cadáver
Cirurgia assistida por computador
Estudo comparativo
Joelho/cirurgia
Ligamento cruzado anterior/cirurgia
Abstract in Portuguese
INTRODUÇÃO: A precisão no posicionamento dos túneis ósseos na reconstrução do ligamento cruzado anterior do joelho (LCA) é considerado um dos fatores fundamentais para o bom resultado dessa cirurgia. A cirurgia ortopédica auxiliada por computador (computer aided orthopedic surgery CAOS) é um avanço tecnológico que tem como um dos principais objetivos exatamente o aumento da precisão. OBJETIVO: comparar o posicionamento do centro dos túneis e a isometria do enxerto obtidos com o uso de um sistema de navegação computadorizada (Orthopilot) e com o uso de guias cirúrgicos convencionais. MÉTODOS: 36 joelhos pareados de cadáveres tiveram o LCA ressecado por artroscopia no Laboratório de Artroscopia do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo. Um joelho de cada par foi ramdomizado para o grupo 1 (guias cirúrgicos convencionais) e o outro para o grupo 2 (Orthopilot). Um fio de sutura inelástico foi passado pelo centro dos túneis tibial e femoral confeccionados para a reconstrução do LCA, sem que os túneis fossem finalmente brocados. Todos os joelhos foram então analisados quanto ao posicionamento do centro do túnel tibial (distância do LCP, distância da tubérculo intercondilar medial da tíbia e distância do corno anterior do menisco lateral), do centro do túnel femoral (distância da cortical posterior e angulação coronal na fossa intercondilar do fêmur) e a variação da distância entre os pontos centrais do túnel femoral para o túnel tibial em flexão de 90º e em extensão (isometria). Os dados foram analisados segundo o teste de Wilcoxon para comparação de duas amostras pareadas. RESULTADOS: A variação da distância entre o tunel femoral e tibial em flexão e extensão (isometria) foi maior no grupo 1 convencional, do que no grupo 2 Orthopilot (grupo 1: média 4,2mm com intervalo de 1,1mm a 9,4mm versus grupo 2: média 2,8mm com intervalo de 0,3mm a 6,7mm; p<0,05). Os outros parâmetros analisados não tiveram diferença estatística entre os grupos e demonstraram que todos os túneis dos dois grupos estavam bem posicionados de acordo com os critérios adotados. CONCLUSÕES: O emprego de instrumental cirúrgico navegado pelo sistema Orhtopilot permitiu o posicionamento dos túneis ósseos da reconstrução do LCA de maneira tão precisa quanto os guias cirúrgicos convencionais utilizados. Mais do que isso, proporcionou um posicionamento significativamente mais isométrico nessa série
Title in English
Surgery computer assisted, Anterior cruciate ligament/surgery, Comparative study, Cadaver, Knee/surgery, Arthroscopy
Keywords in English
Anterior cruciate ligament/surgery
Arthroscopy
Cadaver
Comparative study
Knee/surgery
Surgery computer assisted
Abstract in English
INTRODUCTION: Precise tunnel location has been considered to be very important to achieve good results in anterior cruciate ligament (ACL) reconstruction surgery. Computer Aided Orthopedic Surgery (CAOS) is a technology improvement whose main objective is to enhance precision. PURPOSE: To compare the accuracy of tunnel placement and graft isometry for ACL reconstruction performed with the use of a computer-assisted navigation system (Orthopilot) and with traditional instruments. METHODS: 36 matched-paired cadaveric knees had their intact ACL removed by arthroscopy at the Arthroscopy Laboratory Orthopedic Department of University of São Paulo Medical School. One knee of each pair was randomized to group 1 (traditional instruments) or group 2 (Orthopilot). An inelastic suture was then passed through the center of where would be the tibial tunnel and then through the center of where would be the femoral tunnel. None of the tunnels were actually drilled. All knees were then dissected and 6 parameters were obtained: The distance from the tibial tunnel center to: 1) the PCL; 2) the lateral meniscus anterior horn; 3) the medial tibial spine. 4) The distance from the femoral tunnel center to the posterior femoral cortex. 5) The femoral tunnel coronal angle. 6) The variation of the distance from the femoral to the tibial tunnels with the knee extended and in 90 degree flexion. The data were submitted to statistical analysis and compared with the Wilcoxon Matched Pairs Test. RESULTS: The variation of the distance from the femoral to the tibial tunnels in flexion and extension was smaller in the Orthopilot group (better isometry): group 1: mean 4.2 mm (1.1-9.4 mm); group 2: mean 2.8 mm (0.3-6.7 mm) p<0,05. All other parameters showed no statistical difference between the groups and all tunnels were considered to be in satisfactory positions. DISCUSSION: There was no difference in tunnel position between the groups. Better isometry was achieved in the Orthopilot group compared to conventional instruments
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
FabioJAngelini.pdf (2.42 Mbytes)
Publishing Date
2009-04-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.