Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2010.tde-24082010-171112
Document
Author
Full name
Fernando Cal Garcia Filho
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Guarniero, Roberto (President)
Lourenco, Alexandre Francisco de
Matos, Marcos Antonio Almeida
Title in Portuguese
Estudo comparativo entre a capsulorrafia com sutura simples e com âncora em quadris de coelhos
Keywords in Portuguese
Âncoras de sutura
Biomecânica
Coelho Nova Zelândia
Modelo de animal experimental
Quadril/cirurgia
Abstract in Portuguese
INTRODUÇÃO: A displasia do desenvolvimento do quadril (DDQ) é uma das patologias mais relevantes e polêmicas que acometem as crianças desde o nascimento. A anatomia tridimensional, a complexidade da articulação do quadril, o pouco conhecimento sobre o potencial de remodelação acetabular após luxação ou sub-luxação e as sequelas na marcha e na movimentação suscitam várias discussões sobre esse tema. A revisão bibliográfica a respeito dos diferentes tipos de capsulorrafia é muito pouco discutida entre os pesquisadores. Técnicas menos agressivas e que possibilitem maior resistência à recidiva da luxação após a redução cruenta devem ser pesquisadas. OBJETIVO: a presente pesquisa busca, por meio de ensaios biomecânicos, comparar as capsulorrafias com sutura simples e com âncoras, em quadris de coelhos. MATERIAL E MÉTODO: Foram utilizados 13 coelhos, 26 quadris, todos machos da raça Nova Zelândia albinos (Oryctolagus cuniculus). Inicialmente, realizamos um projeto piloto em três coelhos (06 quadris). Este experimento constou de 10 coelhos, divididos em 02 grupos: o grupo 1 submetido à capsulorrafia (quadris direito e esquerdo) com sutura simples utilizando fio absorvível de ácido poliglicólico e o grupo 2 submetido a capsulorrafia (quadris direito e esquerdo) com âncora de titânio. Após o período de quatro semanas de operados, todos animais foram submetidos à eutanásia e seus quadris congelados. Após um descongelamento prévio das peças no mesmo dia das análises biomecânicas, foram avaliados os parâmetros da rigidez (Rig), força máxima (Fmax), deformidade máxima (Dmax) e energia (E). RESULTADO: não houve diferença estatisticamente significante em relação à força no limite de proporcionalidade, rigidez e força máxima entre os grupos com sutura simples e com âncora. CONCLUSÃO: Por meio dos ensaios biomecânicos, tendo como parâmetro a rigidez (Rig), força máxima (Fmax), deformidade máxima (Dmax) e energia (E), ficou demonstrado que as capsulorrafias em quadris de coelhos com sutura simples e com âncora são semelhantes entre si.
Title in English
Comparative evaluation between capsulorrhaphy with simple suture and with anchor in rabbit hip joints
Keywords in English
Biomechanics
Experimental animal models
Hip/surgery
New Zealand rabbit
Suture anchor
Abstract in English
INTRODUCTION:HDD (Hip Development Dysplasia) is one of the most important and controversial pathologies which affect children. The threedimensional anatomy and complexity of the hip joint, as well as the little understanding of the potential of acetabular reconstruction after luxation or sub-luxation and the later effects on the child's gait and movement, raise various points of discussion. Little literature exists about the different types of capsulorrhaphy. Techniques which are less aggressive or decrease risk of luxation after surgical reduction must be researched. OBJECTIVE: Using biomechanical studies, this research aims to compare hip capsulorrhaphy in rabbits, carried out with two different techniques: capsulorrhaphy with simple sutures and with anchors. MATERIAL AND METHOD: Thirteen New Zealand Albino (Oryctolagus cuniculus) male rabbits, twenty-six hip joints, were used. First, a pilot project was performed with three rabbits (six hip joints). The experimental group consisted of ten rabbits and was divided in two sub-groups: group 1 underwent capsulorrhaphy on both right and left hips with simple suture using polyglocolic acid absorbable thread, and group 2 underwent capsulorrhaphy with titanium anchors. After a four-week postoperation period, the animals were euthanized and the hip joints were frozen. On the same day the hip joints were unfrozen, a biomechanical study was carried out, evaluating the following parameters: rigidity, maximum force, maximum deformity and energy. RESULTS: There was no relevant statistical difference in rigidity, maximum force, maximum deformity and energy between the simple suture and anchor groups. CONCLUSION: Through biomechanical analyses, using parameters of rigidity, maximum force, maximum deformity and energy, it has been shown that a capsulorrhaphy with simple suture and with an anchor has similar results in rabbit hip joints.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-08-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.