Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2006.tde-17102014-143936
Document
Author
Full name
Valquiria Greco Arenas
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
David Neto, Elias (President)
Barbosa, Dulce Aparecida
Castro, Maria Cristina Ribeiro de
Title in Portuguese
Avaliação da qualidade de vida de pacientes com insuficiência renal crônica em tratamento por diálise peritoneal automatizada e hemodiálise utilizando o instrumento SF-36
Keywords in Portuguese
Diálise peritoneal
Diálise renal
Insuficiência renal crônica
Qualidade de vida
Questionários
Abstract in Portuguese
INTRODUÇÃO: A avaliação da QV tem se destacado de modo crescente em pesquisas clínicas de pacientes com insuficiência renal crônica terminal (IRCT), sendo o SF-36 um dos instrumentos mais utilizados nesta população. O objetivo deste estudo foi avaliar e comparar a QV nos pacientes com IRCT que estavam em tratamento dialítico de DPA e HD utilizando o SF-36 e avaliar se parâmetros sociais, demográficos, econômicos, clínicos e de adequação em diálise interferem na QV desses grupos. MÉTODOS: este estudo transversal, prospectivo e observacional, foi realizado em uma unidade de diálise satélite no município de São Paulo, em dezembro de 2003. Foram incluídos no estudo os pacientes de DPA ou HD, com tempo na terapia maior que 90 dias, idade entre 18 e 75 anos, com domínio da língua portuguesa e que concordaram em responder o instrumento para avaliação da QV. Participaram 22 pacientes de DPA e 79 de HD. Através do prontuário médico, foram coletados dados demográficos, sociais, econômicos, informações clínicas e exames laboratoriais. A QV foi avaliada apenas uma vez durante entrevista com a pesquisadora. Os valores obtidos na QV foram cruzados com as demais variáveis para verificar se havia interação significativa. RESULTADOS: Os grupos foram muito semelhantes entre si na maioria das variáveis analisadas. Na HD observou-se tempo maior de tratamento (p=0.002) e níveis de albumina sérica mais elevados que DPA (p<0,001). Em DPA, mais pacientes possuíam seguro saúde privado (p=0,018). A avaliação da QV é semelhante em quase todos os domínios do SF-36, a única diferença significativa ocorreu no Aspecto Físico, onde HD teve um escore maior que DPA (p=0,007). Não ocorreu nenhuma interação significativa entre este domínio e as demais variáveis analisadas que justificasse a diferença encontrada. CONCLUSÃO: A QV foi muito semelhante entre as duas modalidades de diálise. O grupo de HD apresentou melhor resultado em relação ao Aspecto Físico, sendo que este fato parece depender unicamente do método dialítico
Title in English
Evaluation of Quality of Life of end-stage renal disease patients treated with either automatic peritoneal dialysis or hemodialysis using SF-36 questionnaires
Keywords in English
Chronic kidney failure
Peritoneal dialysis
Quality of life
Questionnaires
Renal dialysis
Abstract in English
The evaluation of health-related Quality of Life (Qol) is fundamental when searching for better treatment in end-stage renal disease (ESRD). The SF-36 is the most used questionnaire for this population. The purpose of this study was evaluated and compared the Qol in ESRD patients during either automatic peritoneal dialysis (APD) or hemodialysis (HD) treatment using the SF-36. METHODS: this is a prospective, cross-sectional and observational study, performed in a single dialysis facility in the city of São Paulo. Patients, with an age between 18 and 75 years, should be for more than 90 days in therapy and besides showing fluency in Portuguese language should be able to understand the questionnaire. Twenty-two APD and 79 HD patients were enrolled. The social, demographics, economics, clinical and laboratories information were colleted from the electronic data base. The Qol was assessed once an interview with one of the authors. The scores of SF-36 was correlated with the others variables to verify possible interactions. RESULTS: Both groups were very similar in most of the analyzed variables. Time in therapy was longer (p=0.002) and serum albumin level was higher (p<0,001) for the HD group than APD. In APD group more patients had private health insurance (p=0,018). The scores of SF-36 were similar in the various dimensions of the Qol questionnaire. The mean score for Physical Functioning was higher in HD than in APD (p=0,007). No significant interactions between the SF-36 dimensions and the others variables explained this difference. CONCLUSION: The Qol was very similar between these two dialysis modalities. The HD group showed better scores in Physical Functioning and this seemed to depend on the type of dialysis modality only
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
ValquiriaGrecoArenas.pdf (858.40 Kbytes)
Publishing Date
2014-10-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.