• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2011.tde-07102011-114405
Documento
Autor
Nombre completo
Luciana Pereira Malta de Alencar
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Medeiros, Felipe de Araujo Andrade (Presidente)
Cohen, Ralph
Damico, Francisco Max
Silva, Maria Rosa Bet de Moraes
Tavares, Ivan Maynart
Título en portugués
Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma
Palabras clave en portugués
Diagnóstico por imagem
Disco óptico
Fibras nervosas
Glaucoma/diagnóstico
Laser/uso diagnóstico
Prognóstico
Progressão da doença
Resumen en portugués
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas
Título en inglés
Predictive value of optic disc topography for the development of glaucoma
Palabras clave en inglés
Disease progression
Glaucoma/diagnostic
Imaging diagnosis
Laser/diagnostic use
Nerve fibers
Optic disc
Prognosis
Resumen en inglés
Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-10-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.