• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2005.tde-26012006-163810
Document
Auteur
Nom complet
Alexandre Antonio Marques Rosa
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Nakashima, Yoshitaka (Président)
Casella, Antonio Marcelo Barbante
Helal Junior, John
Mion Junior, Décio
Moraes, Lucio Ribeiro de
Titre en portugais
"Monitorização ambulatorial da pressão arterial de pacientes com oclusão do ramo da veia central da retina"
Mots-clés en portugais
HIPERTENSÃO ARTERIAL/epidemiologia
MONITORIZAÇÃO AMBULATORIAL DA PRESSÃO ARTERIAL
OCLUSÃO DA VEIA RETINIANA
PRESSÃO ARTERIAL
Resumé en portugais
Avaliou-se a prevalência de hipertensão arterial sistêmica (HAS) e a variação circadiana da pressão arterial (PA), através da Monitorização ambulatorial da pressão arterial (MAPA), em pacientes com oclusão do ramo da veia central da retina (ORVCR). Foram avaliados, prospectivamente, 93 casos/olhos de 83 pacientes. A ausência do descenso fisiológico da PA durante o sono ("non-dipper") foi definida como diminuição da pressão sistólica = 10% e a presença de descenso quando este valor fosse maior ("dipper"). Há uma prevalência extremamente alta (94%) de HAS em pacientes com ORVCR. Entre os hipertensos, uma grande parcela dos indivíduos "non-dipper" (n=34; 44,2%). Estas evidências sugerem que um nível mais sustentado de PA nas 24 horas possa ser um fator de risco para o desenvolvimento da ORVCR
Titre en anglais
Blood pressure monitoring of branch retinal vein occlusion patients
Mots-clés en anglais
BLOOD PRESSURE
BLOOD PRESSURE MONITORING AMBULATORY
HYPERTENSION/epidemiology
RETINAL VEIN OCCLUSION
Resumé en anglais
Objective: Identifying with Blood pressure monitoring (BPM) in patients with branch retinal vein occlusion (BRVO): high blood pressure (HBP) prevalence, possible cases of white-coat normotension (WCNT) and variation of circadian blood pressure (BP). Methods: Prospectively, 93 cases/eyes of 83 patients with BRVO were evaluated at Ophthalmological Clinic of "Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo" (HCFMUSP). After that, patients were taken to Hypertension League of Nephrology Chair of HCFMUSP (LH-HCFMUSP) for clinical evaluation and blood pressure monitoring. Non-dipper was defined as a fall in systolic blood pressure = 10%, and dipper when this value was higher
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2006-02-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.