Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2018.tde-31102018-133522
Documento
Autor
Nombre completo
Fernando Uliana Kay
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2018
Director
Tribunal
Júnior, Edson Amaro (Presidente)
Hochhegger, Bruno
Leite, Claudia da Costa
Souza, Rogério de
Szarf, Gilberto
Título en portugués
Parâmetros quantitativos obtidos por tomografia computadorizada de dupla-energia na avaliação da perfusão pulmonar em modelo experimental de embolia e lesão pulmonar
Palabras clave en portugués
Embolia pulmonar
Imagem radiográfica a partir de emissão de duplo fóton
Lesão pulmonar aguda
Modelos animais
Suínos
Tomografia computadorizada de multidetectores
Tomografia computadorizada quadridimensional
Resumen en portugués
Nesta tese, buscou-se avaliar se a tomografia computadorizada de duplaenergia pós-contraste (TCDE) é capaz de detectar diferenças regionais da perfusão pulmonar em um modelo animal suíno incluindo variações de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, comparando estes resultados com os obtidos pela perfusão de primeira passagem com a tomografia computadorizada dinâmica (TCD). Dez suínos landrace foram divididos em Grupos A (N = 5, controle) e B (N = 5). Animais do Grupo B foram submetidos ao protocolo de lesão alveolar induzida por ventilação mecânica (LPIV). O volume sanguíneo perfundido e o fluxo sanguíneo pulmonar foram, respectivamente, estimados pela TCDE (%VSPTCDE) e pela TCD (FSPTCD), em diversas condições experimentais: posição supina versus prona, presença versus ausência de LPIV, presença ou ausência de oclusão da artéria pulmonar. A correlação entre %VSPTCDE e FSPTCD foi moderada (R = 0,60) com ampla variabilidade (intervalo 0,35-0,91) entre animais. %VSPTCDE e FSPTCD demonstraram padrões similares de heterogeneidade da perfusão pulmonar nas diferentes condições experimentais. Entretanto, reduções do %VSPTCDE causadas pela oclusão com balão foram em média -29,32 %, enquanto reduções do FSPTCD foram em média -86,78 % (p < 0,001). Estimativas quantitativas do VSPTCDE tiveram um erro médio de +4.3 ml/100g em comparação com o FSPTCD, com limites de concordância de 95 % entre -16,6 ml/100g e 25,1 ml/100g. A TCDE póscontraste é capaz de prover estimativas semiquantitativas que refletem a heterogeneidade regional da perfusão pulmonar causada por mudanças de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, apresentando moderada correlação com a perfusão de primeira passagem pela TCD
Título en inglés
Quantitative parameters obtained from dual-energy computed tomography in the evaluation of pulmonary perfusion in an experimental model of embolism and alveolar damage
Palabras clave en inglés
Acute lung injury
Four-dimensional computed tomography
Models animal, Swine
Multidetector computed tomography
Pulmonary embolism
Radiography dual-energy scanned projection
Resumen en inglés
We aimed to evaluate whether contrast-enhanced dual-energy CT (DECT) detects regional pulmonary perfusion changes in a swine model of acute lung injury, with variations in decubitus and transient occlusion of the pulmonary artery, comparing these results with those obtained with dynamic CT perfusion (DynCT). Ten landrace swine were assigned to Groups A (N = 5, control) and B (N = 5). Group B was subjected to ventilator-induced lung injury (VILI). Perfused blood volume and pulmonary blood flow were quantified by DECT (PBVDECT) and DynCT (PBFDynCT), respectively, under different settings: supine versus prone, and with/without balloon occlusion of a pulmonary artery (PA) branch. Correlation of regional PBVDECT versus PBFDynCT was moderate (R = 0.60) with high variability (range 0.35-0.91) among the animals. Regional pulmonary perfusion changes assessed by %PBVDECT agreed with PBFDynCT in response to decubitus changes, lung injury and balloon occlusion in the multivariate analysis. However, reductions in %PBVDECT caused by balloon occlusion were in average -29.32 %, whereas reductions in PBFDynCT were in average -86.78 % (p < 0.001). Quantitative estimates of PBVDECT had a mean bias of +4.3 ml/100g in comparison with PBVDynCT, with 95 % confidence intervals between -16.6 ml/100g and 25.1 ml/100g. Semiquantitative contrastenhanced DECT reflects regional changes in perfusion caused decubitus changes, acute lung injury, and balloon occlusion of the PA, with moderate correlation in comparison with DynCT
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
FUKayOriginal.pdf (3.09 Mbytes)
Fecha de Publicación
2018-10-31
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.