• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2018.tde-14032018-115705
Document
Author
Full name
Ricardo Vieira Carlos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2017
Supervisor
Committee
Carmona, Maria Jose Carvalho (President)
Cavalcanti, Ismar Lima
Tanaka, Pedro Paulo
Tardelli, Maria Angela
Torres, Marcelo Luis Abramides
Title in Portuguese
Efeito da estimulação tetânica, prévia à  calibração, no início de ação e tempos de recuperação do bloqueio neuromuscular em pacientes pediátricos
Keywords in Portuguese
Anestesia geral
Bloqueadores neuromusculares
Criança
Junção neuromuscular
Monitorização neuromuscular
Pediatria
Pré-escolar
Abstract in Portuguese
Introdução e objetivos: a monitorização neuromuscular objetiva é prática médica baseada em evidências e deve ser empregada rotineiramente quando do uso de fármacos bloqueadores neuromusculares. Entretanto, pesquisas relacionadas a esta monitorização em pacientes pediátricos não estão vastamente documentadas como nos adultos. Em pesquisa clínica, o monitor neuromuscular deve apresentar resposta estável (menor que 5% de variação na altura de T1) por um período de dois a cinco minutos antes da administração do bloqueador neuromuscular. O tempo necessário para se alcançar esta estabilidade na resposta pode variar, mas pode ser encurtado por meio da aplicação de um estímulo tetânico por cinco segundos. Aventouse a hipótese de que a aplicação de estímulo tetânico antes da calibração poderia levar a diferenças nos parâmetros de início de ação e nos tempos de recuperação. O objetivo primário deste estudo foi comparar o tempo de início de ação e os tempos de recuperação após dose única de rocurônio 0,6 mg/kg seguido de recuperação espontânea, entre dois grupos de pacientes com sequências diferentes para a calibração (com e sem o uso de estímulo tetânico). Os objetivos secundários foram a avaliação da altura inicial e final de T1, tempo para se obter estabilidade da altura de T1 e os seguintes ajustes do monitor neuromuscular: corrente elétrica e sensibilidade. Método: consentimento informado dos responsáveis, foram incluídos no estudo 50 pacientes, estado físico 1 ou 2, de dois a 11 anos, agendados para cirurgias abdominais e/ou perineais com tempo cirúrgico estimado superior a 60 minutos. Os pacientes (25 por grupo) foram submetidos a anestesia intravenosa e alocados randomicamente para receber estímulo tetânico (grupo T) ou não (grupo C), antes da calibração do monitor. Após a calibração do monitor, a modalidade sequência de quatro estímulos foi iniciada e mantida em intervalo de 15 segundos. Resultados: não houve diferença significativa no início de ação (C: 57,5±16,9 versus T: 58,3±31,2 s; p=0,917). O tempo normalizado para as relações da sequência de quatro estímulos 0,7, 0,8 e 0,9 diferiram significativamente entre os grupos (C: 40,1 ± 7,9 versus T: 34,8±10 min; p=0,047, C: 43,8±9,4 versus T: 37,4±11 min; p=0,045 e C: 49,9±12,2 versus T: 41,7±13,1 min; p=0,026, respectivamente). O tempo necessário para a estabilização da altura de T1 não mostrou diferença estatística entre os grupos (C: 195±203 versus T: 116±81,6 s; p=0,093). Os valores de altura inicial de T1 mostraram diferença significativa entre os grupos (C: 98 versus T: 82,7%; p < 0,001). Os valores de altura final de T1 também mostraram diferença significante entre os grupos (C: 95,3 versus T: 69,3%; p < 0,001). Conclusões: o estímulo tetânico encurtou o tempo normalizado das relações da sequência de quatro estímulos 0,7, 0,8 e 0,9. As alturas inicial e final de T1 foram menores no grupo tétano. Não houve diferença estatística entre os grupos relativo ao tempo necessário para estabilização da altura de T1. Os ajustes do monitor (corrente elétrica e sensibilidade) não apresentaram diferenças entre os gruposEffect of tetanic stimulation, prior to calibration, on the onset of action and recovery times of neuromuscular blockade in pediatric patients
Title in English
Effect of tetanic stimulation, prior to calibration, on the onset of action and recovery times of neuromuscular blockade in pediatric patients
Keywords in English
Anesthesia general
Child
Child preschool, Neuromuscular blocking agents
Neuromuscular monitoring, Neuromuscular junction
Pediatrics
Abstract in English
Background and objective: objective neuromuscular monitoring is evidence-based medical practice and should be routinely used when using neuromuscular blocking drugs. However, research related to this monitoring in pediatric patients is not widely documented as in adults. In clinical research, the neuromuscular monitor should have a stable response (less than 5% change in T1 height) for a period of two to five minutes before administration of the neuromuscular block agent. The time required to achieve this stability in response may vary, but may be shortened by the application of a tetanic stimulus for 5 seconds. It was hypothesized that the application of tetanic stimulus prior to calibration could lead to differences in the parameters of onset of action and recovery times. The primary outcome of this study was to compare time to onset and recovery times after single dose rocuronium 0.6 mg.kg-1 followed by spontaneous recovery between two groups of patients with different sequences for calibration (with and without use of tetanic stimulus). The secondary outcomes were the evaluation of the initial and final T1 height, time to obtain stability of T1 height and the following neuromuscular monitor settings: electric current and sensitivity. Methods: after approval by the Institutional Ethics Committee and obtaining the informed consent of those responsible for the patient, were included in the study 50 patients, physical status 1 or 2, from 2 to 11 years, scheduled for abdominal and/or perineal surgeries with estimated surgical time greater than 60 minutes. Patients (25 per group) underwent intravenous anesthesia and were allocated randomly to receive tetanus stimulation (group T) or not (group C) prior to calibration of the monitor. After calibration of the monitor, train-of-four mode was initiated and maintained at interval of 15 seconds. Results: there was no significant difference in onset of action (C: 57,5±16,9 versus T: 58,3±31,2 s; p=0,917). The train-of-four normalized times 0.7, 0.8 and 0.9 differed significantly between the groups (C: 40,1±7,9 versus T: 34,8±10 min; p=0,047, C: 43,8±9,4 versus T: 37,4±11 min; p=0,045 and C: 49,9±12,2 versus T: 41,7±13,1 min; p=0,026, respectively). The time required to stabilize the T1 height did not show statistical difference between the groups (C: 195±203 versus T: 116±81,6 s; p=0,093), The initial values of T1 height showed a significant difference between the groups (C: 98 versus T: 82,7%; p < 0,001). The final T1 height values also showed a significant difference between the groups (C: 95,3 versus T: 69,3%; p < 0,001). Conclusions: the tetanic stimulus shortened the normalized time of the fourstimulus sequence ratios 0.7, 0.8, and 0.9. The initial and final T1 heights were lower in the tetanus group. There was no statistical difference between the groups regarding the time required to stabilize the T1 height. The monitor settings (electric current and sensitivity) did not show differences between groups. Trial registration: Clinicaltrials.gov identifier: NCT0249867
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-03-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.