• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2014.tde-20102014-122256
Documento
Autor
Nombre completo
Alessandro Rodrigues de Carvalho Martins
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Malbouisson, Luiz Marcelo Sá (Presidente)
Bernini, Celso de Oliveira
Chiamolera, Murilo
Nozawa, Emilia
Tanaka, Clarice
Título en portugués
Avaliação da hiperinsuflação pulmonar em felinos domésticos submetidos à ventilação por pressão controlada analisados por meio da tomografia  computadorizada helicoidal
Palabras clave en portugués
Anestesia
Atelectasia pulmonar
Gatos
Lesão pulmonar induzida por ventilação mecânica
Respiração artificial
Respiração com pressão positiva
Tomografia computadorizada por raios X
Resumen en portugués
É sabido que a ventilação mecânica é essencial para oxigenação do sangue e remoção de dióxido de carbono, sendo realizada sobre sedação ou anestesia geral. Contudo, durante à ventilação mecânica, podem ocorrer alterações na estrutura pulmonar caracterizadas por aparecimento de colapso ao final da expiração e zonas de hiperinsuflação alveolar durante a fase inspiratória, podendo levar ao aparecimento de lesão pulmonar associada à ventilação mecânica. Como não existe consenso sobre a melhor estratégia para ventilação mecânica intraoperatória em pequenos animais submetidos a procedimentos cirúrgicos sobre anestesia geral, o objetivo desse estudo foi avaliar a hiperinsuflação pulmonar em diferentes níveis pressóricos nas vias aéreas por meio de tomografia computadorizada em gatos submetidos à anestesia geral. Foram utilizados 17 gatos machos adultos, submetidos à ventilação mecânica a pressão controlada, iniciando a uma pressão de pico de 5cmH2O em "ZEEP", subindo escalonadamente 2 cmH2O a cada 5 minutos, até chegar a 15 cmH2O, em seguida, descendo escalonadamente 2 cmH2O a cada 5 minutos, até chegar a 5 cmH2O. A frequência respiratória foi mantida em 15 movimentos por minuto e o tempo inspiratório em um segundo, independente de seu EtCO2. Imediatamente a cada aumento de pressão, foi realizada uma pausa inspiratória de 4 segundos para realização da imagem tomográfica; dados de mecânica respiratória e gasometria arterial. A pressão inspiratória de 5cmH2O apresentou menores áreas hiperinsufladas (4,68±4,7%) e maiores áreas normoaredas (83,6%±6,24%) em comparação aos outros momentos de subida. A pressão de 5cmH2O demostrou ser a ventilação mais protetora para felinos com pulmão íntegro, pois apresentou a maior área normoaerada com boa oxigenação apesar de apresentar acidemia por acidose respiratória. Fato este que pode ser controlado aumentando a freqüência respiratória e/ou diminuindo o tempo inspiratório
Título en inglés
Evaluation of hyperinflation in domestic cats undergoing pressure-controlled ventilation analyzed with helicoidal CT
Palabras clave en inglés
Anesthesia
Cats
Positive-pressure respiration
Pulmonary atelectasis
Respiration artificial
Tomography X-ray computed
Ventilator-induced lung injury
Resumen en inglés
Mechanical ventilation is crucial to blood oxygenation and carbon dioxide removal during sedation or general anesthesia. However, lung structure alterations may occur during anesthesia induction period, characterized by emergence of end-expiration collapse and alveolar overinsuflation zones during the inspiratory period, leading to lung injury associated to mechanical ventilation. Since there is no consensus on the best strategy to intraoperative mechanical ventilation in small animals undergoing surgery and general anesthesia, the aim of this study was to evaluate pulmonary hyperinflation at different pressure levels in the airways by computed tomography in cats undergoing general anesthesia. There were used 17 male adult cats undergoing controlled pressure mechanical ventilation, starting at a peak pressure of 5 cmH2O at "ZEEP", rising steeply 2 cmH2O every 5 minutes until reaching 15 cmH2O and then descending steeply each 2 cmH2O 5 minutes until it reached 5 cmH2O. The respiratory rate was maintained at 15 movements per minute and inspiratory time on 1 second, regardless of EtCO2. Immediately each pressure increase, it was performed an inspiratory pause of 4 seconds to perform the tomographic image, collect respiratory mechanic's data and arterial blood gases. inspiratory pressure 5cmH2O had shown lower hyperinflated areas (4,68±4,7%) and larger normoaerated areas (83,6%±6,24%) compared to other times of ascension. The pressure of 5cmH2O demonstrated to be the most protective ventilation for cats with intact lung, because it showed the largest normoaerated area with good oxygenation despite presenting acidemia by respiratory acidosis. This fact can be controlled by increasing or decreasing respiratory rate and inspiratory time
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-10-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.