• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2019.tde-27022019-151124
Document
Author
Full name
Bruno Francisco de Freitas Tonelotto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2018
Supervisor
Committee
Auler Junior, Jose Otavio Costa (President)
Malbouisson, Luiz Marcelo Sá
Mathias, Ligia Andrade da Silva Telles
Neves, Flavio Humberto de Sousa
Title in Portuguese
Determinação da PEEP ideal e avaliação de atelectasia pulmonar com o uso da ultrassonografia durante intraoperatório de cirurgias eletivas
Keywords in Portuguese
Assistência perioperatória
Atelectasia pulmonar
Hiperinflação pulmonar
Linhas H
Manobra de recrutamento
Pulmão/diagnóstico por imagem
Respiração com pressão positiva
Ventilação pulmonar
Abstract in Portuguese
Introdução: A atelectasia intraoperatória ocorre imediatamente após a indução anestésica e pode ser detectada por ultrassom pulmonar (LUS). No entanto, até o momento o LUS não é utilizado para avaliar a hiperdistensão pulmonar. Neste estudo, descreveu-se um método para detectar hiperdistensão pulmonar usando LUS. A tomografia de impedância elétrica (TIE) foi a referência para comparação dos métodos. Métodos: Dezoito (18) pacientes, com 63 ± 6 anos de idade, com pulmões normais, submetidos à cirurgia abdominal inferior. O TIE foi calibrado, realizada a indução anestésica, intubação e ventilação mecânica. Para reverter a atelectasia posterior, realizou-se uma manobra de recrutamento alveolar com o uso de pressão expiratória final positiva (PEEP) 20 cmH20 e pressão aérea do platô 40 cmH2O durante 120 segundos. A titulação PEEP foi então obtida com valores descendentes: 20, 18, 16, 14,12,10, 8, 6 e 4 cmH2O. Os dados de ultrassom e TIE foram coletados em cada nível PEEP e interpretados por dois observadores independentes. O número de linhas H foi contado usando um filtro especial. O teste de correlação de Spearman e a curva ROC foram utilizados para comparar os dados do LUS e TIE. Resultados: O número de linhas H aumentou linearmente com PEEP: de 3 em PEEP 4 cmH2O a 10 em PEEP 20 cmH2O. Cinco linhas H foram o limiar para a detecção de hiperdistensão pulmonar, definida como hiperdistensão na TIE >= 24,5%. A área sob a curva ROC foi 0,947 (IC 95% 0.901-0.976). Conclusão: O LUS intraoperatório detectou hiperdistensão pulmonar em valores descendentes de PEEP. A presença de cinco ou mais linhas H podem ser consideradas como indicando hiperdistensão pulmonar
Title in English
Ideal PEEP and evaluation of pulmonary atelectasia with the use of ultrasonography during intraoperatory of elective surgeries
Keywords in English
H lines
Lung/imaging diagnosis
Perioperative care
Positive-pressure respiration
Pulmonary atelectasis
Pulmonary hyperinflation
Pulmonary ventilation
Recruitment maneuver
Abstract in English
Purpose: Intraoperative atelectasis occurs immediately after anaesthetic induction and can be detected by lung ultrasound (LUS). However, LUS is considered as unable to assess pulmonary hyperinflation. In this study, we propose a method to detect pulmonary hyperinflation using LUS. Electrical impedance tomography (EIT) was the reference method. Methods: We included 18 patients, 63 ± 6-year old, with normal lungs, undergoing lower abdominal surgery. The following protocol was used: EIT was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment maneuver - positive end-expiratory pressure (PEEP) 20 cmH20 and plateau airway pressure 40 cmH2O during 120 sec was performed. PEEP titration was then obtained during a descending trial: 20, 18, 16, 14,12,10, 8, 6 and 4 cmH2O. Ultrasound and EIT data were collected at each PEEP level and analyzed by two independent observers. The number of H lines was counted using a special filter. Spearman correlation test and ROC curve were used to compare LUS and EIT data. Results: The number of H lines increased linearly with PEEP: from 3 at PEEP 4 cmH2O to 10 at PEEP 20 cmH2O. Five H lines was the threshold for detecting pulmonary hyperinflation, defined as a mean decrease in maximum EIT compliance >= 24,5 %. The area under the ROC curve was 0.947 (CI 95% 0.901-0.976). Conclusion: Intraoperative transthoracic LUS can detect pulmonary hyperinflation during a PEEP descending trial. Five or more H lines can be considered as indicating pulmonary hyperinflation in normally aerated lung regions
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-03-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.