Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2012.tde-04042012-111142
Documento
Autor
Nombre completo
Natalia Cristina Lima Rodrigues
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Waitzberg, Dan Linetzky (Presidente)
Burdmann, Emmanuel de Almeida
Pereira, Claudia Cristina Alves
Título en portugués
Análise do desempenho da bioimpedância elétrica e somatória de pregas cutâneas na avaliação da composição corporal em pacientes renais dialíticos
Palabras clave en portugués
Avaliação nutricional
Composição corporal
Hemodiálise
Insuficiência renal crônica
Resumen en portugués
Introdução: Em pacientes com insuficiência renal crônica em tratamento de hemodiálise (HD), existe necessidade de ferramenta simples, segura e eficaz para avaliar a composição corporal (CC) e permitir diagnóstico de suas alterações, com finalidade de planejamento e monitoramento de tratamento nutricional. Objetivo: Em 60 pacientes em insuficiência renal dialítica determinou-se a eficiência da análise de bioimpedância elétrica (BIA) e a somatória das pregas cutâneas (SPC) na estimativa da gordura corporal total. Métodos: Estudo prospectivo, observacional de comparação de gordura corpórea total (GC) e massa magra total (MM) estimadas, antes e após hemodiálise,por BIA multifrequencial e pela SPC com os valores estimados pelo método de referência, pletismografia a ar de deslocamento (PDA). Resultados: A média estimada GC (kg,%) observado por PDA antes da hemodiálise (HD) foi 17,95 kg ± 0,99 (IC 95% 16,00-19,90) e 30,11% ± 1,30 (IC 95% 27,56-32,66); após hemodiálise (HD), foi 17,92 kg ± 1,11 (IC 95% 15,74-20 10) e 30,04% ± 1,40 (IC 95% 27,28-32,79). Em nenhum período do estudo encontrou-se diferença de GC e de MM (para kg e %) estimadas pelo método SPC em comparação com PDA, no entanto, o BIA subestimou a GC e superestimou a MM (para kg e %) quando comparado com PDA. Conclusão: O método SPC mostrou resultados semelhantes aos PDA e pode ser considerado adequado para avaliação GC em pacientes HD. A BIA não foi considerada método para ser utilizado nessas condições
Título en inglés
Performance analysis of bioelectrical impedance analysis and sum of skinfolds in assessing body composition in renal dialysis patients
Palabras clave en inglés
Body composition
Chronic renal failure
Hemodialysis
Nutritional assessment
Resumen en inglés
Introduction: In patients with chronic renal failure on hemodialysis (HD), there is need for simple tool, safe and effective for assessing body composition (BC) diagnosis and allow your changes, with the purpose of planning and monitoring of nutrition therapy. Objective: In 60 patients in renal dialysis efficiency was determined from the analysis of bioelectrical impedance analysis (BIA) and sum of skin folds (SPC) in the estimation of total body fat. Methods: Prospective, observational comparison of total body fat (BF) and total lean mass (LM) estimated before and after hemodialysis by multifrequency BIA and the SPC with the values estimated by the reference method, air displacement plethysmography (PDA). Results: The estimated average GC (kg,%) observed by PDA prior to hemodialysis (AHD) was 17.95 kg ± 0.99 (95% CI 16.00 to 19.90) and 30.11 ± 1.30% (95% CI 27.56 to 32.66), after hemodialysis (DHD) was 17.92 kg ± 1.11 (95% CI 15.74 to 20 10) and 30.04% ± 1.40 (IC 95% from 27.28 to 32.79). At no period of the study there was a difference of GC and MM (for kg and%) estimated by the SPC method compared with PDA, however, the BIA underestimated FFM and overestimated GC (for kg and%) compared to PDA. Conclusion: The SPC method showed similar results to PDA and can be considered adequate for evaluating GC in HD patients. The BIA was not considered to be the method used in these conditions
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-04-11
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.