• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2013.tde-04022014-120855
Documento
Autor
Nombre completo
Gustavo Ieno Judas
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Moreira, Luiz Felipe Pinho (Presidente)
Dallan, Luis Alberto Oliveira
Gomes, Walter José
Kalil, Renato Abdala Karam
Souza, Luiz César Guarita
Título en portugués
Efeito da injeção intratecal de células tronco do cordão umbilical humano na lesão isquêmica da medula espinhal em ratos
Palabras clave en portugués
Aneurisma da aorta torácica
Células-tronco
Complicações pós-operatórias/terapia
Doenças da aorta/cirurgia
Isquemia do cordão espinhal
Paraplegia
Ratos Wistar
Resumen en portugués
INTRODUÇÃO: A isquemia da medula espinhal continua sendo uma importante complicação nas cirurgias das doenças da aorta descendente torácica e toracoabdominal. OBJETIVOS: Células-tronco são capazes de promover a regeneração do tecido nervoso. Células-tronco derivadas do cordão umbilical humano (CTCUH) são fortes candidatas para uso nas lesões da medula espinhal devido à sua baixa imunogenicidade e pronta disponibilidade. O estudo avaliou os efeitos da administração de CTCUH na lesão isquêmica da medula espinhal em ratos. MÉTODOS: Quarenta ratos Wistar receberam injeção intratecal de 10 uL de solução de HemoHes (6 %) e albumina humana (20 %) contendo 1x104 CTCUH, 30 minutos antes (grupo Tcpré; n=10) e 30 minutos após (grupo Tcpós n=10) oclusão da aorta torácica descendente através de um balão intraluminal por 12 minutos. Os grupos controle receberam apenas a solução de Hemohes (6 %) e albumina humana (20 %) (grupo Cpré; n=10 e grupo Cpós; n=10). O período observacional, para avaliação da função motora dos animais, foi de 28 dias. Cortes de três segmentos tóraco-lombares da medula espinhal foram submetidos à análise histológica e imunohistoquímica para detecção de apoptose (TUNEL) e quantificação de células-tronco humanas hematopoiéticas CD45 +. RESULTADOS: Todos os grupos mostraram incidência semelhante de paraplegia e mortalidade. A média de pontuação da função motora não mostrou diferença durante o período observacional nos grupos, com exceção do grupo Tcpós o qual melhorou de 8,14 ± 8,6 para 14,28 ± 9,8 (p < 0,01). Número de neurônios viáveis foi maior no grupo Tcpós (p=0,14) e a média de apoptose foi mais baixa nesse mesmo grupo (p=0,048), porém sem diferença estatística significativa em relação ao controle. Foi confirmada a presença de células CD45 + quatro semanas após a injeção intratecal em ambos os grupos terapêuticos, principalmente, no grupo Tcpós. CONCLUSÕES: A injeção intratecal de CTCUH é factível e melhora a função motora da medula espinhal em um modelo de oclusão endovascular da aorta torácica descendente
Título en inglés
Effect of intrathecal injection of human umbilical cord blood stem cells in spinal cord ischemic compromise in rats
Palabras clave en inglés
Aortic aneurysm thoracic
Aortic diseases/surgery
Paraplegia
Postoperative complications/therapy
Rats Wistar
Spinal cord ischemia
Stem cells
Resumen en inglés
BACKGROUND: Spinal cord ischemia remains a complication after surgical repair of descending and thoracoabdominal aortic diseases. OBJECTIVES: Stem cells have the potential to induce nervous tissue regeneration processes. Human stem cells derived from the umbilical cord are one of strong candidates used in cell therapy for spinal cord injury due to weak immunogenicity and ready availability. We sought to evaluate the use of Human Umbilical Cord Blood Stem Cells (HUCBSC) attenuates the neurologic effects of spinal cord ischemia. METHODS: Fourty Wistar rats received intrathecally injection of 10 uL Hemohes (6 %) and human albumin (20 %) solution contained 1x104HUCBSC, 30 minutes before (Tcpré group; n=10) and 30 minutes after (Tcpós group; n=10) descending thoracic aortic occlusion by intraluminal balloon during 12 minutes. Control groups received only PBS solution (Cpré group; n=10 and Cpós group; n=10). During a 28-day observational period, animals motor function was assessed. Three segments of thoraco-lombar spinal cord specimens were analyzed for histologic and immunohistochemical assessment for detection and quantification of human hematopoietic cells CD45+ and apoptosis (TUNEL). RESULTS: All groups showed similar incidence of paraplegia and mortality. The mean motor function scores showed no difference during time, excepting for Tpos group which improved from 8.14(8.6) to 14.28(9.8)(p < 0,01). Number of viable neurons was higher in Tcpós group (p = 0.14) and apoptosis average was lower in the same animals (p = 0.048), but showed no difference with its respective control. We confirmed the presence of CD45+ cells four weeks after intrathecal injection in both therapeutic groups but mainly in Tpos group. CONCLUSIONS: Intrathecal transplantation of HUCBSC is feasible and improved spinal cord function in a model of endovascular descending aortic occlusion
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
GustavoIenoJudas.pdf (1.71 Mbytes)
Fecha de Publicación
2014-02-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.