• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2015.tde-09112015-161415
Document
Auteur
Nom complet
Lucas Matos Fernandes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Fernandes, Paulo Manuel Pego (Président)
Barbosa, Fabio Colagrossi Paes
Mariani, Alessandro Wasum
Samano, Marcos Naoyuki
Titre en portugais
Comparação entre duas soluções de recondicionamento pulmonar em pulmões humanos não-aceitos para transplante em modelo de avaliação e recondicionamento pulmonar ex vivo
Mots-clés en portugais
Estudo comparativo
Lesão pulmonar aguda
Preservação de órgãos
Transplante de pulmão
Resumé en portugais
INTRODUÇÃO: O transplante pulmonar é terapia reconhecida de tratamento de doenças terminais pulmonares. Os pulmões, entretanto, são muito susceptíveis às transformações hormonais e hidroeletrolíticas ocorridas no doador após a morte encefálica. As baixas taxas de aproveitamento dos pulmões alavancam pesquisas e meios de utilizar pulmões considerados nãoideais. Um desses modelos é o recondicionamento pulmonar ex-vivo concebido por Steen, no qual se utiliza uma solução hiperosmolar (Steen Solution®) para avaliação e melhora dos pulmões doados. Consideramos que o desenvolvimento de uma solução de recondicionamento pulmonar produzida no Brasil seria conveniente aos serviços de transplante e aos pacientes. Foram comparadas a solução de recondicionamento Steen Solution® e uma solução de fabricação nacional em modelo de ex vivo de pulmões humanos não aceitos para transplante, através da avaliação da mecânica ventilatória, hemodinâmica, trocas gasosas e histologia. MÉTODOS: Foram utilizados 16 pulmões de doadores em morte encefálica, considerados inadequados para o transplante pulmonar. Os pulmões foram submetidos à captação habitual e acondicionados sob isquemia fria por 10 horas. Após este período, os pulmões foram designados, por sorteio, para reperfusão com a solução padrão (Steen solution®) ou a solução nacional por 1h em modelo ex vivo. A lesão pulmonar foi estudada através de parâmetros gasométricos, resistência pulmonar e complacência pulmonar. Foram medidos os pesos em três tempos e relação peso úmido/peso seco após a reperfusão para avaliação de edema. A partir de biópsias seriadas era calculado um score de lesão tecidual e grau de apoptose. RESULTADOS: A capacidade de oxigenação foi de 498,00 ± 37,53 mmHg no grupo STEEN e 521,00 ± 55,43 mmHg no grupo SRNac (p = 0,348). A capacidade relativa de oxigenação calculada ao final do recondicionamento foi 501,37 ± 207,77 no grupo STEEN e 470,30 ± 232,41 no grupo SRNac (p=0,782). Os pesos dos pulmões nos três momentos de avaliação foram: início da isquemia: STEEN = 1.026 ± 451 g, SRNac = 745 ± 282 g (p = 0,180); fim da isquemia: STEEN = 998 ± 391 g, SRNac = 738 ± 316 g (p = 0,184); e fim da reperfusão: STEEN = 1.097 ± 526 g, SRNac = 743 ± 248 g (p = 0,163). A relação peso úmido/peso seco foi 3,63 ± 1,26 no grupo SRNac e 2,06 ± 0,28 no grupo STEEN (p = 0,009). A resistência vascular pulmonar foi 787,99 ± 367,23 dina.s.cm-5 no grupo STEEN e 1.026,81 ± 1.112,53 dina.s.cm-5 no grupo SRNac (p = 0,575). A complacência pulmonar média foi 46,75 ± 20,99 mL/cmH2O no grupo STEEN e 49,74 ± 26,11 cmH2O no grupo SRNac (p = 0,809). O Escore de Lesão Pulmonar foi: STEEN = 4,38 ± 1,51 e SRNac = 4,50 ± 1,77 (p = 0,881). O número de células apoptóticas foi: STEEN = 2,4 ± 2,0 cel/mm2 e SRNac = 4,8 ± 6,9 cel/mm2 (p = 0,361). CONCLUSÕES: Os pulmões reperfundidos com a solução de recondicionamento de fabricação nacional apresentaram características morfológicas e funcionais similares aos que foram reperfundidos com a solução STEEN®, apesar do maior edema encontrado no grupo da solução nacional
Titre en anglais
Comparison between two pulmonary reconditioning solution in human lungs non-accepted for transplantation with an ex vivo lung assessment and reconditioning model
Mots-clés en anglais
Acute lung injury
Comparative study
Lung transplantation
Organ preservation
Resumé en anglais
INTRODUCTION: Lung transplantation is routine treatment of end-stage lung diseases. The lungs, however, are very susceptible to hormonal and electrolyte changes occurred in the donor after brain death. The low recovery rates of the lungs leverage researches and ways to use lungs considered non-ideal. One such model is the lung ex vivo reconditioning designed by Steen, in which using a hyperosmolar solution (Steen Solution®) for evaluation and improvement of donor lungs. We believe that the development of a pulmonary reconditioning solution produced in Brazil would be convenient to transplantation service and patients. Were compared the standard Steen Solution® and a national manufacturing solution in ex vivo model with human lungs not accepted for transplant, through the evaluation of respiratory mechanics, hemodynamics, gas exchange and histology. METHODS: 16 brain-dead donors lungs, considered unsuitable for lung transplantation, were used. The lungs were harvest as usual, packed and stored in cold ischemia for 10 hours. After this period, the lungs were appointed by randomization to reperfusion with the standard solution (Steen Solution®) or national solution for 1 h in ex vivo model. Lung injury was accessed by blood gas parameters, lung resistance and lung compliance. The weights were measured in three times and the after reperfusion wet weight / dry weight ratio for evaluation of edema. The degree of apoptosis and tissue injury score was calculated from serial biopsies. RESULTS: The oxygenation capacity was 498.00 ± 37.53mmHg in STEEN group and 521.00 ± 55.43mmHg in SRNac group (p = 0.348). The relative oxygenation capacity calculated at the end of the reconditioning was 501.37 ± 207.77 in the STEEN group and 470.30 ± 232.41 in the SRNac group (p = 0.782). The weights of lungs in the three stages of evaluation were: onset of ischemia: STEEN = 1,026 ± 451g, SRNac = 745 ± 282g (p = 0.180); end of ischemia: STEEN = 998 ± 391g, SRNac = 738 ± 316g (p = 0.184); and the end of reperfusion: STEEN = 1,097 ± 526g, SRNac = 743 ± 248g (p = 0.163). The wet weight / dry weight ratio was 3.63 ± 1.26 in SRNac group and 2.06 ± 0.28 in STEEN group (p = 0.009). Pulmonary vascular resistance was 787.99 ± 367.23dina.s.cm-5 in STEEN group and 1026.81 ± 1112.53dina.s.cm-5 in SRNac group (p = 0.575). The Lung Injury Score was: STEEN = 4.38 ± 1.51 and SRNac = 4.50 ± 1.77 (p = 0.881). The number of apoptotic cells was: STEEN = 2.4 ± 2.0 cells / mm 2 and SRNac = 4.8 ± 6.9 cells / mm2 (p = 0.361). CONCLUSIONS: The lungs reperfused with national manufacturing reconditioning solution presented morphological and functional characteristics similar to those reperfused with STEEN® solution despite the greater edema found in the group of national solution
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-11-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.