• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2005.tde-27012006-093709
Document
Auteur
Nom complet
Josué Viana de Castro Neto
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Oliveira, Sergio Almeida de (Président)
Dallan, Luis Alberto Oliveira
Dinkhuysen, Jarbas Jakson
Fonseca, José Honório de Almeida Palma da
Hueb, Alexandre Ciappina
Titre en portugais
"Estudo comparativo entre os enxertos arteriais compostos e os enxertos arteriais isolados na revascularização do miocárdio: análise do fluxo sangüíneo e da reserva de fluxo coronariano com Doppler intravascular"
Mots-clés en portugais
ARTÉRIA RADIAL
ARTÉRIAS MAMÁRIAS
REVASCULARIZAÇÃO MIOCÁRDICA/métodos
VELOCIDADE DO FLUXO SANGÜÍNEO
Resumé en portugais
O objetivo é comparar o fluxo sanguíneo total (FS) e a reserva de fluxo coronariano (RFC) aos ramos revascularizados pelas artérias torácica interna esquerda (ATIE) e radial (AR) nos enxertos compostos com os enxertos isolados. Foi realizado um ensaio clínico randomizado de 42 pacientes que foram distribuídos em grupo A ou ATIE e AR composta em Y(n=14), grupo B ou ATIE e AR composta modificada(n=14) e grupo C ou ATIE pediculada para DA e AR aorto-coronariana(n=14). Os pacientes foram submetidos a fluxometria no pós-operatório imediato. A RFC foi de 2,1 ± 0,44, 1,96 ± 0,3 e 2,06±0,42 nos grupos A,B e C, (p=0.7208 A, B x C) e o FS, em ml/min, foi 110±30, 145±59 e 136±58, respectivamente (p=0.3232 A,B x C). Concluindo, não houve diferença significativa do FS total e nem da RFC nos grupos estudados
Titre en anglais
Comparative study between composite and independent arterial grafts in myocardial revascularization : blood flow and coronary flow reserve analysis by intravascular Doppler
Mots-clés en anglais
BLOOD FLOW VELOCITY
MAMMARY ARTERIES
MYOCARDIAL REVASCULARIZATION/methods
RADIAL ARTERY
Resumé en anglais
The objective is to compare the total blood flow (Bf) and coronary flow reserve (CFR) to the left coronary branches that were revascularized with left internal thoracic (LITA) and radial artery (RA) in composite and independent arterial grafts. A randomized trial was realized and 42 patients assigned in group A or composite LITA-RA in a Y configuration (n=14), group B or modified composite LITA-RA(n=14) and group C or pedicled LITA to LAD and aorto-coronary RA (n=14). Patients were submitted to postoperative Bf velocity analysis. CFR was 2,1 ± 0,44, 1,96 ± 0,3 e 2,06±0,42 in groups A,B and C (p=0.7208 A, B x C) and Bf, in ml/min, was 110±30, 145±59 and 136±58, respectively (p=0.3232 A, B x C). In conclusion there was no difference in Bf and CFR in the groups studied
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2006-02-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.