• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.5.2005.tde-27012006-093709
Documento
Autor
Nome completo
Josué Viana de Castro Neto
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2005
Orientador
Banca examinadora
Oliveira, Sergio Almeida de (Presidente)
Dallan, Luis Alberto Oliveira
Dinkhuysen, Jarbas Jakson
Fonseca, José Honório de Almeida Palma da
Hueb, Alexandre Ciappina
Título em português
"Estudo comparativo entre os enxertos arteriais compostos e os enxertos arteriais isolados na revascularização do miocárdio: análise do fluxo sangüíneo e da reserva de fluxo coronariano com Doppler intravascular"
Palavras-chave em português
ARTÉRIA RADIAL
ARTÉRIAS MAMÁRIAS
REVASCULARIZAÇÃO MIOCÁRDICA/métodos
VELOCIDADE DO FLUXO SANGÜÍNEO
Resumo em português
O objetivo é comparar o fluxo sanguíneo total (FS) e a reserva de fluxo coronariano (RFC) aos ramos revascularizados pelas artérias torácica interna esquerda (ATIE) e radial (AR) nos enxertos compostos com os enxertos isolados. Foi realizado um ensaio clínico randomizado de 42 pacientes que foram distribuídos em grupo A ou ATIE e AR composta em Y(n=14), grupo B ou ATIE e AR composta modificada(n=14) e grupo C ou ATIE pediculada para DA e AR aorto-coronariana(n=14). Os pacientes foram submetidos a fluxometria no pós-operatório imediato. A RFC foi de 2,1 ± 0,44, 1,96 ± 0,3 e 2,06±0,42 nos grupos A,B e C, (p=0.7208 A, B x C) e o FS, em ml/min, foi 110±30, 145±59 e 136±58, respectivamente (p=0.3232 A,B x C). Concluindo, não houve diferença significativa do FS total e nem da RFC nos grupos estudados
Título em inglês
Comparative study between composite and independent arterial grafts in myocardial revascularization : blood flow and coronary flow reserve analysis by intravascular Doppler
Palavras-chave em inglês
BLOOD FLOW VELOCITY
MAMMARY ARTERIES
MYOCARDIAL REVASCULARIZATION/methods
RADIAL ARTERY
Resumo em inglês
The objective is to compare the total blood flow (Bf) and coronary flow reserve (CFR) to the left coronary branches that were revascularized with left internal thoracic (LITA) and radial artery (RA) in composite and independent arterial grafts. A randomized trial was realized and 42 patients assigned in group A or composite LITA-RA in a Y configuration (n=14), group B or modified composite LITA-RA(n=14) and group C or pedicled LITA to LAD and aorto-coronary RA (n=14). Patients were submitted to postoperative Bf velocity analysis. CFR was 2,1 ± 0,44, 1,96 ± 0,3 e 2,06±0,42 in groups A,B and C (p=0.7208 A, B x C) and Bf, in ml/min, was 110±30, 145±59 and 136±58, respectively (p=0.3232 A, B x C). In conclusion there was no difference in Bf and CFR in the groups studied
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2006-02-14
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.