• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2007.tde-24102007-125106
Documento
Autor
Nombre completo
Marília D'Elboux Guimarães Brescia
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Massarollo, Paulo Celso Bosco (Presidente)
Coelho, Fabricio Ferreira
Fernandes, Paulo Manuel Pego
Gonzalez, Adriano Miziara
Sankarankutty, Ajith Kumar
Título en portugués
Estudo prospectivo aleatorizado comparando a eficiência clínica dos métodos convencional ou piggyback na drenagem venosa do fígado transplantado
Palabras clave en portugués
Eficiência
Ensaiods clínicos controlados aleatórios
Estudos prospectivos
Pressão venosa
Transplante de fígado/métodos
Veias hepáticas
Resumen en portugués
O objetivo desta pesquisa é comparar a eficiência clínica dos métodos convencional ou piggyback de transplante de fígado (Tx) na reconstrução do efluxo venoso do enxerto. Adicionalmente, pretende-se comparar a eficácia da drenagem venosa do enxerto hepático em diferentes modalidades do método piggyback. Foram estudados 32 pacientes submetidos a Tx pelo método convencional (n=15) ou piggyback (n=17). A pressão da veia hepática livre (PVHL) foi medida por catéter introduzido na veia hepática direita (VHD) do enxerto e a pressão venosa central (PVC) por catéter de Swan-Ganz. As medidas de pressão foram realizadas após a revascularização do enxerto. Gradiente PVHL-PVC superior a 3 mm Hg foi encontrado em 26,7% (4/15) no grupo convencional e 17,6% (3/17) no grupo piggyback (p=0,678). A mediana do gradiente PVC-PVHL foi de 2 mm Hg (0-8 mm Hg) no grupo convencional e 3 mm Hg (0-7 mm Hg) no piggyback (p=0,734). A creatinina sérica (Cr) foi medida no pré-operatório, do 1º ao 7º dia pós-operatório (PO) e no 14º, 21º e 28º PO. A Cr global pós-operatória, calculada pela área sob a curva da Cr vs tempo, foi significativamente maior no grupo convencional (2,04 ± 0,89 vs. 1,41 ± 0,44 mg/dL; p=0,02). Não houve diferença estatisticamente significante entre os grupos quanto à ocorrência de insuficiência renal aguda (p=0,120), definida como Cr maior ou igual a 2,0 mg/dL, quanto ao desenvolvimento de ascite maciça (p=1,000) e em relação à sobrevida dos pacientes (p=0,316). O gradiente PVHL-PVC foi significativamente menor nos casos em que o óstio da VHD é utilizado para reconstrução da via de drenagem venosa no Tx piggyback (1,4 ± 1,4 mm Hg vs. 3,9 ± 1,7 mm Hg; p=0,005). Conclui-se que pacientes submetidos a Tx pelos métodos convencional e piggyback apresentam resultados semelhantes em relação à drenagem venosa do enxerto, ao desenvolvimento de ascite e à sobrevida. Os valores de Cr no PO imediato são significantemente maiores no método convencional. Nos pacientes submetidos a Tx pelo método piggyback, o gradiente PVHL-PVC é menor nos casos em que o óstio da VHD do receptor é incluído para implantação da VCI do enxerto.
Título en inglés
Prospective randomized trial comparing the clinical efficiency of conventional versus piggyback method in venous drainage of the transplanted liver
Palabras clave en inglés
Efficiency
Hepatic veins
Liver transplantation/methods
Prospective studies
Randomized controlled trials
Venous pressure
Resumen en inglés
The aim of this study is to compare the clinical efficiency of hepatic venous outflow reconstruction in conventional and piggyback method of liver transplantation (LTx). The efficacy of the different types of reconstruction of venous drainage in the piggyback liver transplantation was analyzed by a second purpose. Thirty two patients submitted to LTx by conventional method (n=15) or piggyback method (n=17) were studied. Free hepatic venous pressure (FHVP) was measured using a catheter introduced in right hepatic vein (RHV). Central venous pressure (CVP) was obtained through Swan-Ganz catheter. Pressure measurements were performed after graft reperfusion. A FHVP-CVP gradient higher than 3 mm Hg was observed in 26.7% (4/15) of the conventional and in 17.6% (3/17) of the piggyback patients (p=0.678). Median FHVP-CPV gradient value was 2 mm Hg (0-8 mm Hg) in the conventional and 3 mm Hg (0-7 mm Hg) in the piggyback group (p=0.734). Serum creatinine (Cr) was measured on postoperative days 1 to 7, 14, 21 and 28. Postoperative overall Cr, calculated by area under the curve of Cr vs. time, was significantly higher in conventional group (2.04 ± 0.89 vs. 1.41 ± 0.44 mg/dL; p=0.02). There is no significant difference between the groups regarding occurrence of acute renal failure (p=0,120), defined by Cr maior ou igual a 2,0 mg/dL, development of massive ascites (p=1,000) and patient survival (p=0,316). In piggyback LTx patients, FHVP-CVP gradient was significantly lower when the ostium of the RHV of the recipient is used for venous drainage reconstruction (1.4 ± 1.4 mm Hg vs. 3.9 ± 1.7 mm Hg; p=0.005). In conclusion, patients submitted to conventional or piggyback method of LTx have similar results regarding venous outflow, development of ascites and survival. The postoperative Cr values are significantly higher in conventional method. Patients submitted to piggyback LTx present a lower FHVP-CVP gradient when the ostium of the RHV of the recipient is included for implantation of the graft inferior vena cava.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
mariliadegbrescia.pdf (8.06 Mbytes)
Fecha de Publicación
2007-11-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.