• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2009.tde-09122009-162729
Documento
Autor
Nombre completo
Renata Escorcio
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Caromano, Fátima Aparecida (Presidente)
Assis, Silvana Maria Blascovi de
Fu, Carolina
Título en portugués
Elaboração e análise de confiabilidade de escala de avaliação funcional  da manobra de Gowers e da passagem de bipedestação para sedestação no solo para portadores de distrofia muscular de Duchenne (DMD)
Palabras clave en portugués
Avaliação
Distrofia muscular de Duchenne
Doenças musculares
Exame físico
Resumen en portugués
Objetivo: Construir Escala de Avaliação Funcional do Sentar e Levantar do Solo para Portadores de DMD (EAF-2) e testar sua confiabilidade intra e interexaminadores. Método: A construção da escala ocorreu em etapas: 1. Análise do movimento de sentar e levantar do solo em crianças saudáveis. 2. Análise do movimento de sentar e levantar do solo em crianças com DMD. 3. Elaboração da primeira versão da escala e do manual de instrução. 4. Avaliação por peritos e reajustes gerando a versão final. 5. Análise de confiabilidade inter e intraexaminador e correlação com a Escala de Vignos, idade e tempo de execução da atividade. Resultados: A escala abrange três fases para o sentar e cinco para o levantar, cada fase contendo itens que devem ser avaliados e pontuados. O escore pode variar de 0 a 10 para o sentar e de 0 a 15 para o levantar. Foi demonstrado muito boa repetibilidade da medida do sentar e levantar (ICC = 0,89 e 084, respectivamente) e excelente reprodutibilidade (ICC = 0,93 e 0,92, respectivamente). O Coeficiente Kappa para as 8 fases na análise interexaminadores variou de 0,77 a 1,00 (confiabilidade excelente para 5 fases e substancial para 3 fases), e na análise intra-examinador variou de 0,80 a 1,00 (confiabilidade excelente para 6 fases e substancial para 2 fases). Encontrou-se boa correlação entre as variáveis idade x Escala de Vignos (r= 0,58) e levantar x Escala de Vignos (r= 0,56), enquanto que nas variáveis restantes a correlação foi baixa.Conclusão: A EAF-2 é um instrumento de avaliação confiável que permite avaliar a atividade de sentar e levantar em portadores de DMD de forma detalhada e operacionalizada.
Título en inglés
Elaboração e análise de confiabilidade de escala de avaliação funcional da manobra de Gowers e da passagem de bipedestação para sedestação no solo para portadores de distrofia muscular de Duchenne (DMD)
Palabras clave en inglés
Evaluation
Muscular diseases
Muscular dystrophy Duchenne
Physical examination
Resumen en inglés
Objective: Construct the Scale of Functional Evaluation of Sit-and-Stand from the Ground for Patients with DMD (EAF-2) and to test its reliability intra and interexaminer. Method: The construction of the scale occurred in stages: 1. Analysis of the movement to sit and stand from the ground in healthy children. 2. Analysis of the movement to sit and stand from the ground in children with DMD. 3. Elaboration of the first version of the scale and the manual of instruction. 4. Evaluation by experts and readjustments generating the final version. 5. Analysis of Reliability inter and intra-examiner and correlation with the Vignos Scale, age and time length for the execution of the activity. Results: The scale comprehends three phases for the sitting and five for the standing, each phase with items that must be evaluated and scored. The score may vary from 0 to 10 for the sitting and from 0 to 15 for the standing. A very good repeatability of the measure of sitting as well as of standing was demonstrated (ICC = 0,89 and 084, respectively) and excellent reproducibility (ICC = 0,93 and 0,92, respectively). The Kappa Coefficient for the 8 phases in the interexaminer analysis varied from 0,77 to 1,00 (excellent reliability for 5 phases and substantial for 3 phases), and in the intra-examiner analysis varied from 0,80 to 1,00 (excellent reliability for 6 phases and substantial for 2 phases). Good correlation was found between the variable age x Vignos Scale (r= 0,58) and to stand x Vignos Scale (r= 0,56), whereas in the remaining variable the correlation was low. Conclusion: The EAF-2 is a trustful instrument of evaluation that allows to evaluate the activity of sitting and standing in people with DMD in a detailed and operationalized way.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
RenataEscorcio.pdf (881.27 Kbytes)
Fecha de Publicación
2010-01-07
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • ESCORCIO, R., et al. Caracterização da passagem de bipedestação para sedestação no solo e da passagem de decúbito dorsal no solo para bipedestação em crianças normais. Revista de Terapia Ocupacional da Universidade de São Paulo [online], 2007, vol. 18, p. 44-46. Dispon?vel em: http://www.crefito.com.br.
  • ESCORCIO, R., et al. Development of an evaluation scale for sitting and standing from ground for children with Duchenne muscular dystrophy. Journal of Motor Behavior [online], 2011, vol. 43, p. 31-36. Available from: http://www.ncbi.nlm.nih.gov/pubmed?term=caromano.
  • FERNANDES, Lilian Aparecida Yoshimura, et al. Elaboração e confiabilidade da escala de avaliação funcional do subir e descer escada para distrofia muscular de Duchenne. Revista Brasileira de Fisioterapia [online], 2010, vol. 14, p. 518-526. Dispon?vel em: http://www.ncbi.nlm.nih.gov/pubmed?term=caromano.
  • HUKUDA, M. E., et al. Evaluation Scale Development, Reliability for Sitting and Standing From the Chair for Duchenne Muscular Dystrophy [doi:10.1080/00222895.2012.760513]. Journal of Motor Behavior [online], 2013, vol. 45, p. 117-126.
  • HUKUDA, Michele Emy, et al. Caracterização e tempo da atividade funcional de sentar e levantar da cadeira por meninos saudáveis. ConScientiae Saúde , 2010, vol. 9, p. 402-406.
  • SILVA, Ronaldo Luis da, et al. Efeito do feedback visual na força isométrica da pinça de três dedos. ConScientiae Saúde , 2009, vol. 8, p. 447-450.
  • FERNANDES, Lilian Aparecida Yoshimura, et al. Influência do feedback visual na realização da força máxima isométrica. In XVII Congresso Brasileiro de Fisioterapia, São Paulo, 2007. Revista Brasileira de Fisioterapia.São Carlos : UFSCar, 2007. Resumo.
  • SILVA, Ronaldo Luis da, et al. Efeitos da reeducação respiratória em idosas sedentárias. In XVII Congresso Brasileiro de Fisioterapia, São Paulo, 2007. Revista Brasileira de Fisioterapia.São carlos : UFSCar, 2007. Resumo.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.