• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2014.tde-08042014-110142
Document
Auteur
Nom complet
Priscila Santos Albuquerque
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2013
Directeur
Jury
Caromano, Fátima Aparecida (Président)
Fu, Carolina
Assis, Silvana Maria Blascovi de
Titre en portugais
Desenvolvimento de software para aplicação de escala de avaliação funcional de pessoas com distrofia muscular de Duchenne e testagem de usabilidade
Mots-clés en portugais
Avaliação da deficiência
Distrofia muscular de Duchenne/reabilitação
Distrofias musculares/reabilitação
Fisioterapia
Software
Validação de programas de computador
Resumé en portugais
Devido à carência de avaliações para Distrofia Muscular de Duchenne (DMD), fisioterapeutas desenvolveram e testaram a confiabilidade da Functional Evaluation Duchenne Muscular Dystrophy (FES-DMD). Visando otimizar sua aplicação foi necessário um software. O objetivo deste estudo foi desenvolver e testar a usabilidade de software para aplicação da FES-DMD. Para desenvolver o software foi necessário um engenheiro, um programador e uma fisioterapeuta. Após finalização foi realizada avaliação técnica por cinco pareceristas e aplicado teste de usabilidade com quinze fisioterapeutas especialistas, para avaliar o uso do software na prática clínica e coletar o tempo de aplicação da FES-DMD. De acordo com as características exigidas o software foi desenvolvido com especificações: linguagem Visual Basic. Net, base de dados SQL Compact Server, Plataforma Windows XP sp3 ou superiores, Hardware de suporte, tela com resolução 1024X768 e formato do vídeo WMV/MP4. Estas permitem que o software tenha banco de dados seguro, cadastro de usuários, visualização de filmes, preenchimento da escala, cálculo do escore e geração de relatório. Como resultados, a avaliação técnica contribuiu com Layout e o teste de usabilidade mostrou que dez de quinze fisioterapeutas concordam fortemente que o software é usável na prática clínica, três concordam, enquanto que um discorda e outro discorda fortemente. Com relação ao tempo de aplicação, a FESDMD no software se mostrou mais rápida (p < 0.001). Foi possível desenvolver software para aplicação da FES-DMD. O instrumento promove ganho de tempo do fisioterapeuta, armazena dados e imagens de forma segura, gera relatórios e é usável na prática clínica
Titre en anglais
Development of software for application of functional assessment scale for people with Duchenne muscular dystrophy and usability testing
Mots-clés en anglais
Disability evaluation
Muscular distrophy Duchenne/rehabilitation
Muscular dystrophies/rehabilitation
Physical therapy specialty
Software
Software validation
Resumé en anglais
Due to the lack of reviews for Duchenne Muscular Dystrophy (DMD), physiotherapists have developed and tested a confiabiliade Functional Evaluation of Duchenne Muscular Dystrophy (FES-DMD). In order to optimize your application was necessary software. The aim of this study was to develop and test the usability of software for application of FES-DMD. To develop the necessary software was an engineer, a programmer and a physiotherapist. After finalizing technical evaluation was carried out for five referees and applied usability testing with fifteen physiotherapists experts to evaluate the use of software in clinical practice and collect the time of application of FES-DMD. According to the characteristics required software has been developed with specifications: Visual Basic language.Net, database SQL Server Compact Platform, Windows XP sp3 or higher, Hardware Support, 1024X768 screen resolution and video format WMV/MP4. These allow the software to be secure database, user registration, inhouse movies, completing the scale score calculation and reporting. As a result, the technical evaluation contributed Layout and usability test showed that ten fifteen physiotherapists strongly agree that the software is usable in clinical practice, three agree, while one disagreed and one strongly disagrees. Regarding the time of application, the FES- DMD in software is faster (p < 0.001). It was possible to develop software for the application of FES- DMD. The instrument promotes gain time physiotherapist, stores images and data securely, generate reports, and is usable in clinical practice
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-04-10
 
AVERTISSEMENT: Le matériau se réfère à des documents provenant de cette thèse ou mémoire. Le contenu de ces documents est la responsabilité de l'auteur de la thèse ou mémoire.
  • ALBUQUERQUE, P. S., et al. Desconforto respiratório em pacientes com DMD e restrição ventilatória grave durante uma sessão de hidroterapia. Cadernos de Pós Graduação em Distúrbios do Desenvolvimento [online], 2012, vol. 12, p. 29-35. Dispon?vel em: http://www.mackenzie.br/fileadmin/Graduacao/CCBS/Pos-Graduacao/Docs/Cadernos/Volume_12/2o_vol_12/Artigo3.pdf.
  • ALBUQUERQUE, P. S., e CAROMANO, F. A. Efeitos da hidroterapia na capacidade vital forçada de paciente com Esclerose Lateral Amiotrófica. Neurociências (Rio de Janeiro), 2013.
  • ALBUQUERQUE, PRISCILA, e CAROMANO, FÁTIMA. Efeitos da Hidroterapia na Capacidade Vital Forçada de Paciente com Esclerose Lateral Amiotrófica [doi:10.4181/RNC.2013.21.845.4p]. Revista de Neurociências (EPM. Impresso) [online], 2013, vol. 21, p. 388-391.
  • FRANZINI, R. V., et al. Avaliação da frequência cardíaca e da pressão arterial em solo e imersão em pacientes com distrofia muscular de Duchenne. Cadernos de Pos-Graduacao em Disturbios do Desenvolvimento [online], 2012, vol. 12, p. 108-111. Dispon?vel em: http://www.mackenzie.br/mestrado_bio_caderno_p_g.html.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.