Master's Dissertation
DOI
https://doi.org/10.11606/D.54.1986.tde-19032015-114437
Document
Author
Full name
Hélio Cesar Nogueira Tolentino
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1986
Supervisor
Committee
Rodrigues, Antonio Ricardo Droher (President)
Craievich, Aldo Felix
Cusatis, Cesar
Title in Portuguese
Espectrômetro para EXAFS dispersivo com focalização sagital
Keywords in Portuguese
Não disponível
Abstract in Portuguese
Um novo espectrômetro para estudo de EXAFS em laboratórios, com tubos convencionais de raios-X, é apresentado. Este equipamento faz uso de um monocromador curvo para focalização sagital e usa a divergência na outra direção para fazer a dispersão em energia, permitindo que todos os pontos do espectro sejam coletados simultaneamente. O desempenho do espectrômetro para EXAFS foi avaliado com monocromadores planos e curvos. Aspectos como resolução em energia, redução no tempo de aquisição dos dados experimentais e calibração de energia, foram abordados, mostrando que monocromadores com raios de curvatura tão baixos quanto 60mm apresentam praticamente a mesma resolução em energia que os planos. Nos testes foram utilizadas amostras de Cobre e filmes como detectores unidimensionais
Title in English
Not available
Keywords in English
Not available
Abstract in English
A new dispersive EXAFS spectrometer, for use with conventional laboratory x-ray sources, is presented. The equipment uses curved silicon monochromators for simultaneous focusing and dispersion of the available radiation, so that the whole spectrum is collected at one time. The performance of the spectrometer was studied with both curved and plane monochromators with respect to energy resolution, collection time reduction and energy calibration. The results show that there is practically no resolution deterioration, with respect to the plane monochromators, for radios of curvature as low as 60mm. For these tests x-ray films were used as linear detectors, which can be replaced by other low parallax unidimensional detectors, such as CCd type
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-03-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors