Tesis Doctoral
DOI
https://doi.org/10.11606/T.54.1993.tde-10042015-114440
Documento
Autor
Nombre completo
Rolando Fonseca Fernandes
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1993
Director
Tribunal
Zimmerman, Robert Lee (Presidente)
Faria, Roberto Mendonça
Lejbman, Iuda Dawid Goldman Vel
Robilotta, Cecil Chow
Tannus, Alberto
Título en portugués
Espectros de energia de feixe de elétrons terapêuticos : correlação entre parâmetros físicos e qualidade
Palabras clave en portugués
Não disponível
Resumen en portugués
Apresentamos uma análise e medidas dos espectros de energia dos feixes de elétrons terapêuticos, relacionando-a com a qualidade destes feixes. Parâmetros clínicos e físicos, importantes nos planejamentos radioterápicos e dosimetria das radiações, são analisados detalhadamente a partir de suas definições e as suas dependências com a largura do espectro. As medidas e estudos foram efetuadas com dois acelerados lineares clínicos de modelos diferentes: Mevatron 74 (UNICAMP SP) e Mevatron 12 (HC/FMRP/Ribeirão Preto SP) produzindo feixes de energias nominais variando de 5 a 12 MeV para o primeiro e, 3 a 11 MeV para o segundo. Verificamos que os valores previstos pela teoria semi-empírica para os parâmetros clínicos diferem daqueles medidos. Essas diferenças são importantes quando enfocadas sob a visão do desenho dos aceleradores e os resultados clínicos desejados
Título en inglés
Not available
Palabras clave en inglés
Not available
Resumen en inglés
A new approach was described for clinical and physical parameters used in radiotherapy planning and dosimetry, studying their dependencies on spectral widths. Two different models of clinical linear accelerators were used-Mevatron 74 (UNICAMP/SP) and Mevatron 12 (HC/FMRP/Ribeirão Preto). Mevatron 74 produces beams with nominal energies from 5 up to 12 MeV and Mevatron 12 from 3 up to 11 MeV. It was verified that the values of cilinical parameters expected from a semi-empirical theory differ from that obtained experimentally. Such differences are relevant from the point of view of the design of electron accelerators, as wellas, of the target clinical results
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
RolandoFernandesD.pdf (6.22 Mbytes)
Fecha de Publicación
2015-04-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.