Master's Dissertation
DOI
https://doi.org/10.11606/D.54.1988.tde-14102014-101324
Document
Author
Full name
José Antonio Malmonge
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1988
Supervisor
Committee
Giacometti, José Alberto (President)
Ferreira, Guilherme Fontes Leal
Mergulhão, Sérgio
Title in Portuguese
Técnica de correntes termo-estimulada em circuito aberto. Aplicação ao estudo do transporte de cargas no polímero PETP
Keywords in Portuguese
Circuito aberto
Corrente termo estimulada
PETP
Transporte de cargas elétricas
Abstract in Portuguese
Foi construída uma nova versão de um sistema para medidas de correntes termo-estimuladas em circuito aberto (DTE). Mostrou-se que no Teflon FEP, carregado com corona negativa, os ruídos que aparecem nas curvas de DTE , que são devidos a micro rupturas elétricas na amostra, causam uma variação de potencial considerável na mesma. Verificou-se também que a corrente anômala originada pelo deslocamento de cargas na camada de ar entre a amostra e a placa sensora pode perturbar as medidas de DTE com amostras virgens carregadas positivamente. A inversão de polaridade da corrente nas medidas de DTE na região próxima a temperatura ambiente, foi explicado como sendo devido a variação da capacitância da amostra em função da temperatura. Medidas de DTE, realizadas com o polímero PETP (Mylar), mostraram que o processo de transporte que dá origem ao pico de corrente acima de 100 C é devido a uma condutividade intrínseca originária da geração de portadores em centros neutros de ionização. Essa geração possui uma dependência com o campo elétrico do tipo Poole-Frenkel e a mobilidade dos portadores livres, depende do volume livre o qual tem valor maior que o de equilíbrio abaixo da temperatura da transição vítrea
Title in English
Thermo stimulated technique in open circuit. Application to the investigation of charge transport in PETP polymer
Keywords in English
Electric charge transport
Open circuit
PETP
Thermo stimulated current
Abstract in English
A new version of thermo stimulated current setup (DTE) in open circuit was built. It was shown in measurements electric noise is present in the DTE curve in Tefon FEP negatively charged which is due to micro electric breakdown in the sample. It was also found that the electric current in air gap between the sample surface and the sensor plate can disturb DTE measurements performed in positively charged samples. The polarity inversion on the DTE curves at room temperature range is due to the capacitance variation with the temperature. DTE measurements on PETP (Mylar) showed that the charge transport gives a current peak at 100 C due to an intrinsic conductivity generated by carriers from ionization centers. This process is described by a Poole-Frenkel
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-10-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.