• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.54.1987.tde-15102009-094058
Documento
Autor
Nombre completo
Aparecido Augusto de Carvalho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1987
Director
Tribunal
Oliveira, Sergio Mascarenhas (Presidente)
Cameron, John Roderick
Sanches, Rosemary
Slaets, Jan Frans Willem
Vargas, Helion
Título en portugués
Dosimetria fotoacústica e piroelétrica de radiação x na faixa de diagnostico.
Palabras clave en portugués
Dosimetria
Faixa de diagnóstico
Fotoacústica
Piroelétrico
Raios X
Sensor piroelétrico
Resumen en portugués
Apresentaremos nesta tese três novos tipos de dosímetros de radiação, projetados para medir radiação X, na faixa de diagnóstico: o dosímetro de radiação fotoacústico pulsado, o dosímetro de radiação piroelétrico e o dosímetro de radiação piroelétrico pulsado. Estudamos também o dosimetro de radiação fotoacústico com o objetivo de compará-lo com os novos dosímetros desenvolvidos. Propomos uma metodologia para calibração de um dosímetro fotoacústico que prescinde da calibração de sua resposta em um campo conhecido de radiação ionizante. Apresentaremos um modelo teórico para explicar os resultados obtidos com o dosímetro de radiação piroelétrico pulsado. Os resultados encontrados mostram que os dosímetros desenvolvidos são do tipo calorimétrico, sendo a resposta deles linear com a taxa de fluência de energia da radiação X.
Título en inglés
Photoacoustic and pyroelectric dosimetry in the x ray diagnostic range.
Palabras clave en inglés
Diagnostic range
Dosimetry
Photoacoustic
Pyroelectric
Pyroelectric sensor
X Rays
Resumen en inglés
In this thesis we present three new types of radiation dosimeters, designed to measure X-rays in its diagnostic region: the pulsed photo acoustical radiation dosimeter, the pyroeletric radiation dosimeter and the pulsed pyroelectric radiation dosimeter. We also study the photo acoustical radiation dosimeter with the scope of to compare its characteristics with the characteristics of the new developed dosimeters. We propose a methodology for calibration of a photo acoustical dosimeter which doesn´t require the calibration of its response in a known field of ionizing radiation. We present a theoretical model to explain the results produced by the pulsed pyroelectric radiation dosimeter. The obtained results show that the developed dosimeters are of calorimetric type, being linear its response with the X-ray energy fluency rate.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-11-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.