• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.58.2006.tde-04102006-145650
Document
Author
Full name
Rodrigo Tiossi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2006
Supervisor
Committee
Ribeiro, Ricardo Faria (President)
Antunes, Rossana Pereira de Almeida
Henriques, Guilherme Elias Pessanha
Title in Portuguese
Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica
Keywords in Portuguese
Ligas dentárias
Prótese dentária fixada por implantes
Soldagem a laser
Abstract in Portuguese
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92μm), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10μm e Ti cp: 48,41 ± 26,69μm). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76μm, Ni-Cr: 20,13 ± 7,97μm, e Ti cp: 22,28 ± 17,29μm, e no lado contrário: Co-Cr: 118,64 ± 91,48μm, Ni-Cr: 70,66 ± 20,88μm, e Ti cp: 118,56 ± 51,35μm. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08μm). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81μm) e Ti cp (17,70 ± 11,70μm), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36μm) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15μm) e em Ti cp (40,42 ± 27,14μm) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67μm, após a simulação, quando era 41,02 ± 26,15μm após soldagem a laser para o primeiro e, 40,42 ± 27,14μm e 28,05 ± 20,89μm, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes.
Title in English
Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles
Keywords in English
Dental alloys
Implant supported dental prosthesis
Laser welding
Abstract in English
The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92μm), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10μm e Cp Ti: 48.41 ± 26.69μm). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76μm, Ni-Cr: 20.13 ± 7.97μm, and Cp Ti: 22.28 ± 17.29μm, and on the opposite side: Co-Cr: 118.64 ± 91.48μm, Ni-Cr: 70.66 ± 20.88μm, and Cp Ti: 118.56 ± 51.35μm. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08μm). For the other two groups, Ni-Cr alloy (13.10 ± 1.81μm) and Cp Ti (17.70 ± 11.70μm), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36μm) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15μm) and the Cp Ti (40.42 ± 27.14μm) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67μm, after simulation, when was 41.02 ± 26.15μm after laser welding for the first and, 40.42 ± 27.14μm and 28.05 ± 20.89μm, before and after, for the second, though not showing any statistically significant differences.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2006-11-07
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • DE AGUIAR JúNIOR, Fábio Afrânio, et al. An Alternative Section Method for Casting and Posterior Laser Welding of Metallic Frameworks for an Implant-Supported Prosthesis [doi:10.1111/j.1532-849X.2008.00405.x]. Journal of Prosthodontics [online], 2009, vol. 18, n. 3, p. 230-234.
  • TIOSSI, R., et al. Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks [doi:10.1111/j.1365-2842.2010.02063.x]. Journal of Oral Rehabilitation [online], 2010, vol. 37, n. 5, p. 359-363.
  • TIOSSI, Rodrigo, et al. Comparative Analysis of the Fit of 3-Unit Implant-Supported Frameworks Cast in Ni-Cr, Co-Cr and cpTi. International Journal of Prosthodontics, 2008, vol. 21, n. 2, p. 121-123.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.