• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.59.2014.tde-07102014-113550
Document
Author
Full name
Thatiane Alves Pianoschi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2014
Supervisor
Committee
Nicolucci, Patrícia (President)
Costa, Alessandro Martins da
Ghilardi Netto, Thomaz
Oliveira, Lucas Nonato de
Rodrigues, Letícia Lucente Campos
Title in Portuguese
Estudo de dosimetria gel polimérica em radioterapia com feixes de elétrons utilizando ressonância magnética e simulação Monte Carlo
Keywords in Portuguese
código PENELOPE.
MAGIC-f gel
Radioterapia
Abstract in Portuguese
Radioterapia com feixe de elétrons tem sido empregada, frequentemente, para tratamentos de neoplasias superficiais, devido às características de alcance bem definido e alto gradiente de dose em pouca profundidade. Para que as novas técnicas radioterápicas com esse tipo de feixe possam ser implementadas com segurança é necessária a realização de um controle da qualidade rigoroso. Protocolos recomendam que o controle da qualidade para esse tipo de feixe seja realizado com câmara de ionização, porém dosímetros termoluminescentes, diodos e filmes também são empregados com essa finalidade. Entretanto, esses dosímetros não possuem simultaneamente um conjunto de características essenciais para realização do controle da qualidade, como alta resolução espacial, baixa dependência energética, possibilidade de uso em altos gradientes de dose e distribuição tridimensional de dose. Nesse trabalho avaliou-se a utilização do dosímetro polimérico MAGIC-f gel em aplicações em controle da qualidade em Radioterapia com feixes de elétrons. As leituras das amostras de gel foram realizas por ressonância magnética e simulação Monte Carlo foi utilizada para comparação dos resultados. Como parte de um controle da qualidade para feixe de elétrons, foram determinados parâmetros dosimétricos, como perfil de dose e porcentagem de dose em profundidade, e fatores de qualidade do feixe, como R50, em condições de referência e para campos pequenos. Da comparação entre os dados clínicos e MAGIC-f as diferenças máximas encontradas foram de 4%. Além disso, distribuições de dose de aplicações clínicas com feixes de elétrons foram avaliadas pelo método de comparação do índice gama. Considerando os critérios de 3% e 3 mm, os resultados obtidos para o índice gama mostraram concordâncias acima de 94% para os métodos dosimétricos utilizados. Dessa forma, de acordo com as medidas dosimétricas realizadas com o dosímetro MAGIC-f gel conclui- se que a dosimetria polimérica gel pode ser empregada como uma ferramenta auxiliar em procedimentos de controle da qualidade em Radioterapia com feixes de elétrons, assim como uma ferramenta na determinação das distribuições tridimensionais de dose para feixe de elétrons.
Title in English
Study of polymer gel dosimetry in Radiotherapy with electron beams using magnetic resonance imaging and Monte Carlo simulation.
Keywords in English
MAGIC-f gel
PENELOPE code.
Radiotherapy
Abstract in English
Electron beam radiotherapy has been used frequently for treatments of superficial tumors, due its characteristics of well-defined range and high dose gradient at low depth. For new radiotherapy techniques with this type of beam, a strict quality control is necessary for a safe implementation. Protocols recommend that the quality control for electron beams must be performed with an ionization chamber. However, thermoluminescent dosimeters, films and diodes are also used for this purpose. Although, these dosimeters do not have a set of essential characteristics for performing quality control, like high spatial resolution, low energy dependence, possibility of use in high dose gradients and three dimensional dose distribution acquisition. The present work evaluated the use of MAGIC-f gel dosimeter for the quality control in radiotherapy with electron beams. The readings of the gel samples were made by magnetic resonance imaging and Monte Carlo simulation was used to compare the obtained results. As part of a quality control for the electron beam parameters as percentage depth dose and beam profile were determined. Also beam quality factors, such as R50, were calculated in reference conditions and for small fields. The obtained results were compared with clinical data and MAGIC-f the maximum obtained difference was 4%. In addition, dose distributions from clinical applications with electron beams were evaluated by the gamma index. Considering the criteria of 3% DD and 3 mm DTA, the results showed concordance greater than 94% for all dosimetric methods. Thus, according to the dosimetric measurements through MAGIC-f gel dosimeter it can be inferred that the gel dosimeter can be used as auxiliary tool in the quality control procedures in radiotherapy to electron beam. Also, MAGIC-f is a useful a tool to determine tridimensional dose distributions of electron beam.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-11-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.