• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.59.2013.tde-11112013-115906
Documento
Autor
Nombre completo
Lucas Sacchini Del Lama
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2013
Director
Tribunal
Almeida, Adelaide de (Presidente)
Caliri, Antonio
Caracelli, Ignez
Covas, Dimas Tadeu
Rodriguez, Mario Antonio Bernal
Título en portugués
Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue
Palabras clave en portugués
controle de qualidade
dosimetria e Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT)
dosímetro Fricke Xilenol Gel
Irradiação de sangue
Resumen en portugués
A Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT) é uma reação transfusional rara, porém fatal, que ocorre devido à presença de células T no sangue doado e que pode ser prevenida por meio da irradiação do sangue do doador e de seus componentes antes da transfusão. Assim, o controle de qualidade associado à irradiação do sangue é necessário para se garantir a qualidade do produto transfundido. Neste trabalho é proposta a caracterização e a adaptação da resposta do dosímetro Fricke para uso na dosimetria da irradiação de sangue, mais especificamente o Fricke Xilenol Gel (FXG). Este é um dosímetro químico radiocrômico, que apresenta as vantagens de ser tecido equivalente e de permitir a inferência espacial da dose absorvida dentro da faixa de doses usados na prevenção DECH-AT. Dessa maneira, de modo a possibilitar a inferência de dose absorvida em todo o intervalo utilizado na prevenção da DECH-AT (25 a 50 Gy), o FXG foi caracterizado e adaptado para aplicações dosimétricas envolvendo a irradiação de sangue e derivados. Os resultados com o novo dosímetro apontaram adequabilidade para toda a faixa necessária de doses absorvidas, com sensibilidade e desvanecimento temporal satisfatórios para aplicações rotineiras. Além disso, pela metodologia proposta neste trabalho, foi possível determinar as distribuições espaciais das doses absorvidas com o dosímetro proposto de uma maneira rápida e simples, mostrando assim que este dosímetro apresenta características convenientes para o controle de qualidade para a dosimetria da irradiação de sangue e de hemocomponentes.
Título en inglés
Characterization and Adaptation of Fricke Dosimeter for Blood Irradiation Dosimetry
Palabras clave en inglés
Blood irradiation
Dosimetry
Fricke Xylenol Gel dosimeter
Quality assurance
Transfusion-Associated Graft versus Host Disease (TA-GvHD)
Resumen en inglés
The Transfusion Associated Graft Versus Host Disease (TA-GVHD) is a rare transfusion reaction, however fatal, which develops due to the presence of donor T lymphocytes in the donated blood and that can be avoided by the irradiation of the donated blood blood and blood components prior to transfusion. Thus, the associated quality control of blood irradiation is necessary to guarantee the quality of the transfused product. In this work it is proposed the characterization and adaptation of the response of a Fricke dosimeter to be used for dosimetry of blood irradiation, more especiafically the Fricke Xylenol Gel (FXG). This is a radiochromic chemical dosimeter, which presents advantages to be tissue equivalent and allows the spatial absorbed dose inference. In this manner, in a way to possibilitate the absorbed dose inference in the full interval used for the prevention of the TA-GVHD (25 to 50 Gy) the FXG was characterized and adapted for dosimetry applications involving blood and blood components irradiation. The results with the new dosimeter showed adequability for the necessary absorbed doses, with satisfactory sensibility and time fading for routine applications. Furthermore, according to the methodology proposed in this work, it was possible to determine the spatial absorbed dose distributions with the new dosimeter in an fast and simple way, showing that this dosimeter presents convenient characteristics for dosimetry quality control of irradiated the blood and blood components.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
corrigida.pdf (28.67 Mbytes)
Fecha de Publicación
2014-02-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.