Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2008.tde-20052009-134402
Document
Author
Full name
Thatiane Alves Pianoschi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2008
Supervisor
Committee
Nicolucci, Patrícia (President)
Goes, Evamberto Garcia de
Marques, Paulo Mazzoncini de Azevedo
Title in Portuguese
Avaliação do código de simulação Monte Carlo PENELOPE para aplicações em geometrias delgadas e feixes de radiodiagnóstico
Keywords in Portuguese
PENELOPE
Radiodiagnóstico
Simulação Monte Carlo
Abstract in Portuguese
O uso de códigos de simulação Monte Carlo em radiologia vem crescendo com o aparecimento de diferentes códigos de simulação, desenvolvidos especificamente para aplicações em radiologia, como, por exemplo, PENELOPE. Cada um desses códigos utiliza diferentes algoritmos para o transporte de partículas resultando em diferentes níveis de dificuldade de uso, acurácia nos resultados e desempenho nas simulações. O código de simulação Monte Carlo PENELOPE utiliza um algoritmo misto de transporte da radiação, definido por meio dos parâmetros de entrada da simulação. Normalmente utilizado para aplicações em feixes de altas energias, a influência desses parâmetros no transporte de partículas com o código PENELOPE ainda não foi completamente estabelecida para aplicações que utilizam feixes de radiodiagnóstico e geometrias delgadas. Especificamente em estudos de características dosimétricas de detectores de radiação que possuem espessuras delgadas, como câmaras de ionização, o tipo de algoritmo de transporte pode influenciar nos resultado das simulações. Neste trabalho, o estudo da influência dos parâmetros que controlam o algoritmo de transporte utilizado pelo código de simulação Monte Carlo PENELOPE em feixes de radiodiagnóstico e geometrias delgadas foi realizado através da simulação dos coeficientes de atenuação linear em diferentes materiais, espessuras e energias. A validação desse código nessa faixa de energia permitiu a determinação do fator de retroespalhamento para feixes polienergéticos, contribuindo para sua aplicação em radiodiagnóstico.
Title in English
Evaluation of the PENELOPE Monte Carlo simulation code for applications in thin geometry and radiodiagnostic beams
Keywords in English
Monte Carlo Simulation
PENELOPE
Radiology
Abstract in English
The use of Monte Carlo simulation in radiology has been growing with the appearance of different simulation codes that have been developed specifically for applications in radiology, as for example PENELOPE. Each of these codes use different algorithms for particle transport resulting in different levels of difficulty for its use as well as of accuracy and performance. The PENELOPE code uses a mixed algorithm for radiation transport that is defined by entrance parameters. Most of the applications of PENELOPE code have been performed with high energy beams, however the influence of the entrance parameters in the particle transport is not established for applications evolving radiodiagnostic beams and thin geometries. Specifically for the study of dosimetric characteristics of radiation detectors that have small thicknesses, as ionization chambers, the algorithm transport influences the results of the simulation. In this work, the study of the influence of entrance parameters on the transport algorithm used in PENELOPE Monte Carlo simulation code was performed by the simulation of the linear attenuation coefficients in different materials, thickness and energies used in radiodiagnostic. The validation of this code in such energy range allowed the determination of the backscatter factor for polienergetic beams, aiding its application in radiodianogsis.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.