• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.1993.tde-28042003-170622
Documento
Autor
Nombre completo
Ines Regina Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 1993
Director
Tribunal
Duran, Jose Enrique Rodas (Presidente)
Caliri, Antonio
Vinha, Dionisio
Título en portugués
Estudo da eficiência de aparelhos para fotopolimerizar resinas odontológicas.
Palabras clave en portugués
dureza
fotopolimerizator
intensidade de luz
resina odontológica
Resumen en portugués
Neste trabalho foram caracterizados cinco fotopolimerizadores, Visilux 2, Resilux, Fibralux, Translux III e Primelite. Inicialmente foram obtidos os espectros de emissão das cinco fontes de luz com um monocromador, e a estes espectros foram ajustadas funções gaussianas. Os melhores ajustes foram obtidos com um somatório de funções gaussianas, que originaram uma função matemática característica para cada uma das fontes de luz. Foi obtido também o espectro de absorção ótica da resina composta utilizada, no intervalo de 350-600 nm do espectro eletromagnético, e observou-se que havia uma absorção maior para comprimentos de onda menores. Foram calculados os valores dos coeficientes de atenuação linear para as lamínulas e para as amostras de resina, e observou-se que para uma mesma fonte de luz, haviam variações dos valores do coeficiente de atenuação linear para as diferentes espessuras, tanto das lamínulas como das amostras, concluindo-se que o sistema não estava em equilíbrio. As fontes de luz utilizadas foram ordenadas de acordo com a sua eficiência na polimerização da resina, através dos valores de dureza durante a polimerização da amostra, na seguinte ordem: Visilux 2, Translux III, Resilux, Fibralux, Primelite.
Título en inglés
Analysis of the efficiency from visible-light sources used to polimerize odontological resins.
Palabras clave en inglés
hardness
light intensity
odontological resin
Resumen en inglés
In this work, five photopolymerizators was characterized, Visilux 2, Resilux, Fibralux, Translux III and Primelite. Initially the emission specter from five light sources was obtained with a monochromator, and to these specters was adjusted gaussians functions. The better adjustments was obtained with a sum of gaussian functions, originating a caracteristic mathematical function to each light source. The resin's optical absortion specter was obtained in the 350-600 nm interval from eletromagnetic specter, and was observed that was greater absorption for smaller weavelength. The values of linear attenuation coefficient from slabs and samples was calculated, and was observed that for one light source, there was variations in the values of linear attenuation coefficient to differents thicknesses, both to the slabs and the samples, concluding that the sistem was not in equilibrium. The light sources used was disposed in agreement to their efficience in the resin's polymerization, through the values of the hardness during the photopolymerization, in the order: Visilux 2, Translux III, Resilux, Fibralux and Primelite.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
00-Pre-Textual.pdf (86.53 Kbytes)
01-Capitulos1e2.pdf (11.11 Kbytes)
02-Capitulo3.pdf (77.87 Kbytes)
03-Capitulo4.pdf (95.30 Kbytes)
04-Capitulo5.pdf (11.02 Kbytes)
05-Bibliografia.pdf (12.56 Kbytes)
Fecha de Publicación
2003-05-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.