Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.59.2012.tde-29052012-154558
Documento
Autor
Nome completo
Fernanda Cavalcante
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2012
Orientador
Banca examinadora
Almeida, Adelaide de (Presidente)
Caracelli, Ignez
Pecequilo, Brigitte Roxana Soreanu
Título em português
Avaliação das doses efetivas e efetivas coletivas da radiação natural na região de Ribeirão Preto (SP)
Palavras-chave em português
Cintilador Orgânico Plástico FHT 1376
Dose Efetiva ao Ar Livre
Radiação Natural Terrestrial
Sistema de Informação Geográfica.
Resumo em português
Medidas da radiação gama ambiental foram feitas em algumas regiões da cidade de Ribeirão Preto-SP, de forma a contribuir para o conhecimento acerca dos níveis desse tipo de radiação no estado de São Paulo e no território brasileiro. Escolheu-se determinar as médias anuais de dose efetiva e dose efetiva coletiva, uma vez que estas grandezas levam em conta o risco de possíveis efeitos biológicos associados a exposição à radiação ionizante. Para determinar os valores dessas grandezas, os diversos setores censitários das regiões selecionadas foram mapeados e avaliados individualmente, de acordo com a taxa de dose média absorvida no ar e número de habitantes de cada setor. Utilizou-se um sistema de detecção da radiação gama baseado em cintilador plástico e GPS, que possibilitaram a medida da taxa de dose absorvida no ar a cada segundo, para as coordenadas geográficas selecionadas. Embora este sistema tenha sido desenvolvido para a detecção de fontes artificiais perdidas, ou seja, não tem o objetivo principal de fazer medidas dosimétricas da radiação gama natural, teve seus modos de leitura calibrados e comparados com resultados da literatura (com uma incerteza média de 8,7 %). Dos resultados obtidos, dos mapeamentos realizados nas regiões consideradas, as médias anuais da dose efetiva e dose efetiva coletiva para ambientes ao ar livre foram encontradas com os valores 0,034 ± 0,004 mSv/ano e 25,62 ± 9,25 homem.mSv/ano respectivamente, sendo a primeira cerca da metade da média mundial da dose efetiva recomendada pela UNSCEAR. As médias obtidas são baixas quando comparadas às encontradas em outros estudos sobre dose de radiação gama ao ar livre no estado de São Paulo e em outras regiões do território brasileiro (sendo, de 1,7 até 5,6 vezes menor).
Título em inglês
Effective Dose and Collective Effective Dose Evaluation from Natural Radiation in the Region of Ribeirão Preto (SP)
Palavras-chave em inglês
Geografic Information System.
Natural Terrestrial Radiation
Organic Plastic Scintillator FHT 1376
Outdoor Effective Dose
Resumo em inglês
Gamma environmental radiation measurements were done for some urban regions in the city of Ribeirão Preto-SP, in order to contribute with this knowledge on the annual ambiental values of this type of radiation in the São Paulo state and in the Brazilian territory. The quantities chosen were effective dose and effective collective dose, once they take into account the possible biologic damage related to the ionizing radiation energy absorbed. For the assessments of these quantities, selected census sectors were initially mapped out, regarding their average absorbed dose in air and the number of inhabitants living in each one of the sectors. The detector system used is based on an organic plastic scintillator and a GPS, that allows to obtain the absorbed dose rate for each second and their respective geographic coordinates. Even though this system was developed to detect missing artificial gamma sources, in other words, its main function is not for dosimetric measurements, both display modes were calibrated in exposure rate (R/h) and absorbed dose rate (Gy/h) and their readings were compared to results from the literature (with an average uncertainty of 8.7%). From the mapping results of the selected regions, the annual average effective dose and effective collective dose for outdoor environments were obtained, respectively as 0.034 ± 0.004 mSv/year and 25.62 ± 9.25 man.mSv/year. The value for the first average dose is lower (about half) than the worldwide average value published by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), also lower than the values from other regions in the national territory, regarding the gamma dose rate in outdoor environments (from 1.7 up to 5.6 times lower).
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2012-07-05
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.