• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2014.tde-16092014-153637
Document
Author
Full name
Laís Helena Picolo Bueno
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2014
Supervisor
Committee
Martinis, Bruno Spinosa de (President)
Miranda, Carlos Eduardo Saraiva
Silva, Ricardo Henrique Alves da
Title in Portuguese
Saliva como matriz alternativa na determinação de etanol com aplicação forense
Keywords in Portuguese
Ar Exalado
Cromatografia em Fase Gasosa
Enxaguatórios Bucais
Etanol
Etilômetro
Saliva
Urina
Abstract in Portuguese
Na tentativa de reduzir o número de ocorrência de acidentes de trânsito, o Brasil adotou leis para restringir o consumo de álcool por motoristas e para garantir que as mesmas sejam cumpridas, o contingente policial conta com teste de etilômetro. Ao realizar o teste, se o resultado for positivo para o uso de etanol, o motorista pode ser encaminhado para uma unidade de saúde para que a coleta de sangue seja realizada, para confirmar a presença de etanol ou de outras drogas caso necessário. Porém, pode haver um longo tempo entre a abordagem do motorista e a realização da coleta de sangue, fazendo com que a concentração de etanol no organismo do motorista se altere, além disso, a coleta de sangue é um método invasivo e é necessária a presença de um profissional especializado para que seja realizada. O presente estudo propõe a utilização da saliva como matriz biológica alternativa para dosagem de etanol em motoristas, uma vez que essa matriz permite a dosagem de etanol e de outras drogas, além de permitir que a análise seja repetida, diferentemente do teste do etilômetro, desde que a cadeia de custódia for preservada. Além disso, a coleta dessa amostra não é invasiva, podendo ser realizada no local da abordagem e sob supervisão (coleta vigiada), sem necessitar de profissional especializado. Para verificar se a variação de etanol ao longo do tempo na saliva é semelhante à do ar exalado e da urina, matrizes já utilizadas na dosagem de etanol em motoristas, foi realizado um experimento de ingestão controlada de bebidas alcoólicas por voluntários sadios de maneira controlada, coletando-se amostras de saliva, urina e ar exalado nos tempos de 10, 30, 60 e 90 min após a ingestão. Na segunda etapa do estudo, foi verificado um possível interferente no teste de Etilômetro e na análise de saliva, uma vez que o limite de etanol permitido por lei atual é muito baixo, fazendo-nos questionar se o uso de produtos comuns ao dia a dia e que contém álcool em sua composição, como o enxaguatório bucal, seria capaz de gerar um resultado falso positivo para a ingestão de bebidas alcoólicas. No experimento de interferência, foram testados os seguintes enxaguatórios bucais: Anapyon®, Listerine Cool Mint®, Listerine Cuidado Total®, Cepacol®, Oral B®, Oral B complete®, e ar exalado e saliva foram coletados nos tempos de 5, 10, 15 e 20 minutos. O etanol em amostras de saliva e urina foi determinado por cromatografia em fase gasosa acoplada a detector de ionização por chama (GC-FID) e as amostras de ar exalado foram analisadas no Etilômetro Alcotest 7410 da Dräger.
Title in English
Saliva as an alternative matrix to determine ethanol for forensic purposes
Keywords in English
Breath
Breathalyzer
Ethanol
Gas Chromatography
Mouthwash
Saliva
Urine
Abstract in English
In an attempt to reduce the number of traffic accidents, Brazil has adopted laws to restrict ethanol consumption among drivers, and to guarantee the effectiveness of this law, police officers make use of breathalyzers. When the breathalyzer test is performed, the results can indicate alcohol intake, in this case the driver can be routed to a health unit to collect blood, and then ethanol dosage can be made as well as other drugs if necessary. Therefore, a long time can occur between drivers approach and the blood collection, and the concentration of ethanol in blood can be altered. In addition this sample collection is invasive and needs an specialized personnel to be done. The present study proposes the use of saliva as an alternative biological matrix to ethanol dosage in drivers, once this matrix permits not only the dosage of alcohol but as well as other drugs, and this analysis can be repeated, if the chain of custody has been preserved. Besides, saliva has a non invasive way of collection and can be done under supervision and does require specialized personnel. To verify if the range of ethanol concentration in saliva is the same found in urine and breath, matrixes already used to monitor drivers in traffic, an experiment of alcohol intake in a controlled manner was performed, and urine, saliva and breath were collected in 10, 30, 60 and 90 minutes after alcohol intake. In a second stage of this study, a possible interfering in the breathalyzer test and in saliva analysis was investigated, since the limit if ethanol permitted for drivers in now very low, making us wonder whether the use of products like mouthwashes, that contain ethanol in its composition is capable of generate an false positive result for alcohol intake. It was tested the following mouthwashes: Anapyon, Listerine Cool Mint, Listerine Cuidado Total, Cepacol, Oral B , Oral B complete. Breath and saliva were collected in 5, 10, 15 and 20 minutes after the mouthwashes use. The ethanol in saliva and urine was determined using Gas Chromatography with Flame Ionization Detector (GC-FID), and the ethanol in breath was analyzed using Alcotest 7410 breathalyzer by Dräger.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Corrigida.pdf (1.44 Mbytes)
Publishing Date
2014-11-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.