Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.60.2010.tde-08092010-204549
Documento
Autor
Nome completo
Giovanna de Fatima Moreno Aguiar
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2010
Orientador
Banca examinadora
Barbosa Junior, Fernando (Presidente)
Gomes Neto, José Anchieta
Lanchote, Vera Lucia
Título em português
Determinação de elementos essenciais e tóxicos em sêmen bovino utilizando a espectrometria de massas com plasma acoplado (ICP-MS) com introdução direta da amostra
Palavras-chave em português
bovinos
cela de reação dinâmica
ICP-MS
minerais
sêmen
Resumo em português
Os minerais são de extrema importância no metabolismo geral e no desempenho produtivo e reprodutivo dos bovinos. Atualmente, no Brasil, existem poucos estudos sobre o diagnóstico de deficiências minerais em bovinos, através de análise de macroelementos e elementos traço em fluidos biológicos. A maior parte das informações disponíveis limitam-se ao diagnóstico clínico de deficiências isoladas e à análise de elementos nas pastagens e no solo, que podem sugerir deficiências sub clínicas de alguns minerais, mas apresentam várias limitações e interferências. O objetivo deste trabalho foi desenvolver um método de análise simples, com introdução direta da amostra, utilizando a técnica de q-ICP-MS e DRC-ICP-MS, para determinação de Ca, Cu, Fe, Mg, Zn, I, Mo, As, Se, Ni, Co, Ba, Cs, Mn e Pb em sêmen bovino. Para realização das análises, foi utilizada calibração em meio aquoso e as amostras foram diluídas na proporção 1:50 em solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. Também foram avaliadas a calibração por ajuste de matriz e a análise das amostras após digestão por microondas, para confirmação dos resultados obtidos por introdução direta e calibração em meio aquoso. O DRC foi essencial para determinação de níquel. O gás de reação utilizado foi H2 e os parâmetros RPq e vazão do gás foram estudados para otimização do método. Os limites de detecção para determinação de 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 127I, 98Mo, 75As, 82Se, 59Co, 138Ba, 133Cs, 55Mn e 208Pb foram: 0,262; 0,003; 0,168; 0,004; 0,004; 0,026; 0,007; 0,007; 0,033; 0,002; 0,005; 0,002; 0,003; 0,002 µg L-1 respectivamente, e para determinação de 60Ni por DRC-ICP-MS o LD foi 0,020 µgL-1. O método desenvolvido foi aplicado para determinação de 15 elementos em amostras de sêmen de bovinos de diferentes raças usadas em programas de reprodução e inseminação artificial.
Título em inglês
Determination of essential and toxicant elements in bovine semen using coupled plasma mass spectrometry (ICP-MS) with direct introduction of the sample.
Palavras-chave em inglês
bovines
dynamic reaction cell (DRC-ICP-MS)
ICP-MS
minerals
semen
Resumo em inglês
The minerals are of extreme importance in the general metabolism and in the productive and reproductive performance of the bovines. Nowadays, in Brazil, few studies exist on the diagnosis of mineral deficiencies in bovine, through macroelementos analysis and trace elements in biological fluids. Most of the available information is limited to the clinical diagnosis of isolated deficiencies and the analysis of elements in the pastures and in the soil, that can suggest sub clinical deficiencies of some minerals, but present several limitations and interferences. The objective of this work was to develop a method of simple analysis, with direct introduction of the sample, using the technique of q-ICP-MS and DRC-ICP-MS, for determination of Ca, Cu, Fe, Mg, Zn, I, Mo, As, Se, Ni, Co, Ba, Cs, Mn and Pb in bovine semen. Aqueous medium calibration was used in the analysis and the samples were diluted in the proportion 1:50 in solution containing 0,01% v/v Triton® X-100 and 0,5% v/v of nitric acid. They were also evaluated the matrix matching and the analysis of samples after digestion for microwave, for confirmation of the results obtained by direct introduction and calibration in aqueous medium. DRC went essential for nickel determination. The reaction gas used it was H2 and the parameters RPq and gas flow rate were studied for optimization of the method. The detection limits for determination of 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 127I, 98Mo, 75As, 82Se, 59Co, 138Ba, 133Cs, 55Mn and 208Pb were: 0,262; 0,003; 0,168; 0,004; 0,004; 0,026; 0,007; 0,007; 0,033; 0,002; 0,005; 0,002; 0,003; 0,002 µg L-1 respectively, and for determination of 60Ni for DRC-ICP-MS the LOD was 0,020 µgL-1. The developed method was applied for determination of 15 elements in bovine semen samples of different breed used in reproduction programs and artificial insemination.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
AguiarGFM.pdf (1.65 Mbytes)
Data de Publicação
2011-06-21
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.