Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.60.2010.tde-01122010-135234
Documento
Autor
Nome completo
Tatiana Okura Ajimura
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2010
Orientador
Banca examinadora
Gaitani, Cristiane Masetto de (Presidente)
Carrilho, Emanuel
Oliveira, Anderson Rodrigo Moraes de
Título em português
Análise do mesilato de imatinibe em plasma empregando a eletroforese capilar
Palavras-chave em português
eletroforese capilar
extração líquido-líquido
mesilato de imatinibe
plasma
validação
Resumo em português
O mesilato de imatinibe é um importante fármaco pertencente à classe dos inibidores da tirosina-quinase, desenvolvido e utilizado atualmente no tratamento da Leucemia Mielóide Crônica. No histórico da utilização deste medicamento, casos de resistência tem sido relatados cujos mecanismos envolvidos, além dos mecanismos celulares, podem estar relacionados ao metabolismo aumentado deste fármaco. O imatinibe é metabolizado principalmente pelo CYP 3A4, cuja atividade enzimática apresenta grande variabilidade interindividual e é suscetível a indução ou inibição por inúmeras co-medicações, constituintes ambientais e dietéticos. Sendo assim uma dose do medicamento pode resultar em concentrações plasmáticas muito diferentes entre pacientes. A maior parte dos métodos existentes para a determinação do imatinibe em amostras biológicas utiliza a cromatografia líquida de alta eficiência. Entretanto, o método desenvolvido e validado neste trabalho propôs a utilização da eletroforese capilar para a análise deste fármaco em plasma. Para isto foi utilizado um capilar de sílica fundida (46,5 cm de comprimento total, 38 cm de comprimento efetivo e 50 µm de diâmetro interno), tampão fosfato de sódio 50 mmol/L, pH 2,5 como eletrólito de corrida, injeção hidrodinâmica por 20 s a pressão de 50 mbar, tensão de 30 kV, temperatura de 35 °C e detecção em 200 nm. O procedimento de preparo das amostras foi baseado na extração líquido-líquido com o éter metil-terc-butílico como solvente extrator. Os parâmetros de desempenho analítico, linearidade, precisão, exatidão, recuperação, limite de quantificação, seletividade e estabilidade, avaliados na validação do método, cumpriram os requisitos preconizados na legislação vigente e o método desenvolvido foi validado com sucesso. Além disso, sua aplicação foi demonstrada na análise de amostras de plasma de pacientes portadores de Leucemia Mielóide Crônica.
Título em inglês
Determination of imatinib mesylate in plasma by capillary electrophoresis
Palavras-chave em inglês
capillary electrophoresis
imatinib mesylate
liquid-liquid extraction
plasma
validation
Resumo em inglês
Imatinib mesylate is an important tyrosine kinase inhibitor that has been used for the treatment of Chronic Myeloid Leukemia (CML). Despite the efficacy of imatinib therap, some cases of treatment resistance have been described. A number of mechanisms of resistance have been identified, which include innate or acquired mutations in the BCR-ABL gene, imatinib binding to 1- acid glycoprotein and altered imatinib pharmacokinetics. Imatinib is mainly metabolized by CYP 3A4, whose enzymatic activity presents a large inter-individual variability and is susceptible to induction or inhibition by numerous co-medications, environmental and dietary constituents. Therefore a given dose can yield very different circulating concentrations between patients. The major of methods available for the determination of imatinib in biological samples apply high performance liquid chromatography as analytical technique. However, in this work, we developed and validated a method by capillary electrophoresis for the determination of this drug in human plasma. The analysis was performed using a fused silica capillary (50 µm internal diameter x 46.5 cm total length, 38.0 cm effective length), a 50 mmol/L sodium phosphate buffer pH 2,5 as background electrolyte, hydrodynamic injection time of 20s (50 mbar), voltage of 30 kV, capillary temperature of 35°C and detection at 200 nm. Plasma samples pre-treatment involved liquid-liquid extraction with methyl-terc-butyl ether as extractor solvent. The analytical parameters investigated, linearity, precision, accuracy, recovery, limit of quantification, selectivity and stability, presented in accordance with the confidence criteria established in the literature. Furthermore the application of the method was performed in the analysis of plasma samples from CML patients undergoing treatment with imatinib.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Arquivo.pdf (519.27 Kbytes)
Data de Publicação
2011-01-19
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.