• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.64.1983.tde-20220208-022859
Documento
Autor
Nombre completo
Nelson Nepomuceno
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 1983
Director
Título en portugués
Determinação espectrofotométrica de urânio em rochas e águas naturais empregando sistema de injeção em fluxo
Palabras clave en portugués
ÁGUAS NATURAIS
ANÁLISE POR INJEÇÃO EM FLUXO
ESPECTROFOTOMETRIA
ROCHAS
URÂNIO
Resumen en portugués
Desenvolveu-se um método para a determinação de urânio, em rochas e águas naturais, através da reação com dibenzoilmetano, em fase única, empregando-se um sistema analítico de injeção em fluxo. Foram estudados inicialmente, os fatores que incidiam diretamente sobre a sensibilidade do método proposto, como as concentrações dos reagentes, volumes injetados de amostras, interferentes e melhores condições de acidez para otimização da determinação. Com o sistema de fluxo estabelecido, conseguiu-se uma velocidade analítica de 80 determinações por hora, na faixa de 0,25 a 10 ppm de U. Foi conseguida uma recuperação de 99,93% em análises de amostras reais. Precisão de 97,92%, para medidas de amostras com 4,0 ppm de U, pode ser conseguida. O sistema empregado e detalhes de consumo de reagentes, mascaramento, utilização de material certificado como referência, necessidade de separação prévia para amostras contendo ferro, foram discutidos.
Título en inglés
Spectrofotometric determination of uranium in rocks and natural waters by flow injection analysis
Resumen en inglés
A flow injection procedure for the determination of uranium in rocks and natural waters using reaction with dibenzoilmethane in single phase has been developed. Main sensitivity factors, such as reagent concentrations, sample injected volume, interfering ions and acidity conditions were investigated. The proposed system is characterized by a sampling rate of 80 measurements per hour, in the 0.25 - 10 ppm U range. Recovery of 99.93% in the analysis of real sample was assessed, typical precision of 97.92% for the measurement of a 4.0 ppm U sample was calculated after ten measurements. Systems design and details of reagent consuption, masking, utilization of certified reference materials needed for iron separation prior to sample injection etc are discussed.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
NepomucenoNelson.pdf (4.56 Mbytes)
Fecha de Publicación
2022-02-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.