Determinação espectrofotométrica de urânio em rochas e águas naturais empregando sistema de injeção em fluxo
Mots-clés en portugais
ÁGUAS NATURAIS
ANÁLISE POR INJEÇÃO EM FLUXO
ESPECTROFOTOMETRIA
ROCHAS
URÂNIO
Resumé en portugais
Desenvolveu-se um método para a determinação de urânio, em rochas e águas naturais, através da reação com dibenzoilmetano, em fase única, empregando-se um sistema analítico de injeção em fluxo. Foram estudados inicialmente, os fatores que incidiam diretamente sobre a sensibilidade do método proposto, como as concentrações dos reagentes, volumes injetados de amostras, interferentes e melhores condições de acidez para otimização da determinação. Com o sistema de fluxo estabelecido, conseguiu-se uma velocidade analítica de 80 determinações por hora, na faixa de 0,25 a 10 ppm de U. Foi conseguida uma recuperação de 99,93% em análises de amostras reais. Precisão de 97,92%, para medidas de amostras com 4,0 ppm de U, pode ser conseguida. O sistema empregado e detalhes de consumo de reagentes, mascaramento, utilização de material certificado como referência, necessidade de separação prévia para amostras contendo ferro, foram discutidos.
Titre en anglais
Spectrofotometric determination of uranium in rocks and natural waters by flow injection analysis
Resumé en anglais
A flow injection procedure for the determination of uranium in rocks and natural waters using reaction with dibenzoilmethane in single phase has been developed. Main sensitivity factors, such as reagent concentrations, sample injected volume, interfering ions and acidity conditions were investigated. The proposed system is characterized by a sampling rate of 80 measurements per hour, in the 0.25 - 10 ppm U range. Recovery of 99.93% in the analysis of real sample was assessed, typical precision of 97.92% for the measurement of a 4.0 ppm U sample was calculated after ten measurements. Systems design and details of reagent consuption, masking, utilization of certified reference materials needed for iron separation prior to sample injection etc are discussed.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
NepomucenoNelson.pdf (4.56 Mbytes)
Date de Publication
2022-02-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.