• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.64.2014.tde-03112014-150442
Documento
Autor
Nome completo
Andressa Adame
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Piracicaba, 2014
Orientador
Banca examinadora
Rocha, Fabio Rodrigo Piovezani (Presidente)
Masini, Jorge Cesar
Fatibello Filho, Orlando
Título em português
Sistema de análises em fluxo empregando multicomutação para avaliação de toxicidade aguda com Vibrio fischeri
Palavras-chave em português
Análises em fluxo
Diluições em Linha
Ecotoxicidade
Multi-impulsão
Multicomutação
Poluentes emergentes
Resumo em português
Um sistema de análises em fluxo com multicomutação foi desenvolvido para a mecanização do bioensaio de toxicidade aguda com a bactéria Vibrio fischeri, o qual é baseado na diminuição da luminescência bacteriana causada por espécies tóxicas.Microbombas solenoide foram utilizadas para melhorar as condições de mistura, permitindo também que diluições fossem realizadas em linha com a alteração do volume de amostra e a sobreposição parcial entre a zona da amostra e a suspensão bacteriana. Uma cela de fluxo em espiral, posicionada na janela de emissão de um espectrofluorímetro, foi empregada para as medidas de luminescência e um banho de água construído em laboratório, baseado no efeito Peltier, foi utilizado para manter a temperatura do bioensaio em (13,0±0,1) °C. Um pequeno volume da suspensão bacteriana (120 ?L) foi selecionado visando minimizar o consumo e, consequentemente, os custos do ensaio. O tempo de contato entre a suspensão bacteriana e a amostra foi reduzido para 5 min para aumentar a frequência de amostragem e evitar a atenuação da luminescência devido ao tempo de vida curto das bactérias. Os valores de CE50 para os controles positivos foram estimados em 2,5 ± 0,7, 2,0 ± 0,5 e 10 ± 4 mg L-1 para o Zn(II), Cu(II), e Cr(VI), respectivamente, sendo concordantes com os valores da literatura. Os valores de CE50 para alguns poluentes emergentes (parabenos, cafeína, acetaminofeno, diclofenaco e ácido salicílico) concordaram com os obtidos utilizando o kit comercial BioTox(TM), realizado em micro placa, a nível de confiança de 95 %. Os coeficientes de variação foram estimados em 2,4 e 2 % (n = 10), na ausência e na presença de 0,6 mg L-1 de Zn(II), respectivamente. O sistema de análises em fluxo proposto é, então, uma alternativa simples, rápida, robusta e precisa para a determinação da toxicidade aguda utilizando pequenos volumes de amostra e suspensão bacteriana. Além disso, o sistema apresenta vantagens em comparação com os bioensaios em batelada e em fluxo, tais como ajuste de salinidade e diluições das amostras em linha e a determinação da cinética de toxicidade das espécies químicas
Título em inglês
A multicommuted flow-based system for acute toxicity evaluation with Vibrio fischeri
Palavras-chave em inglês
Ecotoxicity
Emerging pollutants
Flow analysis
In-line dilutions
Multi-pumping
Multicommutation
Resumo em inglês
A multicommuted flow system was developed for automation of the acute toxicity bioassay using Vibrio fischeri bacteria, which exploits the decrease of the bacterial luminescence caused by toxic species. Solenoid micro-pumps were employed to improve mixing conditions and to perform on-line dilutions of the tested compounds by changing the sample volume and exploiting the partial overlap between sample zone and the bacterial suspension. A spiral flow cell, placed at the emission window of a spectrofluorimeter, was employed for signal measurement and a lab-made water bath based on the Peltier effect was used for maintain the temperature of the bioassay at (13.0±0.1) oC. A low volume of the bacterial suspension (120 ?L) was selected in order to minimize its consumption and, consequently, the costs of the assay. The contact time between bacterial suspension and sample was reduced to 5 min to increase the sampling rate and to avoid luminescence fading due to the bacteria short lifetime. EC50 values for positive controls were estimated as 2.5 ± 0.7, 2.0 ± 0.5 and 10 ± 4 for Zn(II), Cu(II), and Cr(VI), respectively, being in agreement with literature values. The EC50 values for some emerging pollutants (parabens, caffeine, acetaminophen, diclofenac and salicylic acid) agreed with those obtained from commercial BioTox(TM) kit performed in micro plate at the 95% confidence level. The coefficients of variation were estimated as 2.4 and 2 % (n=10), in the absence and presence of 0.6 mg L-1 Zn(II), respectively. The proposed flow system is then a simple, fast, robust and accurate alternative for acute toxicity determination, using low sample and bacterial suspension volumes. Furthermore, the system presents advantages in comparison to batch and previous flow-based bioassays, such as the achievement of in-line salinity adjustment and sample dilutions, and the determination of toxicity kinetic for every assayed chemical species
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
AndressaAdame_Revisada.pdf (1,000.68 Kbytes)
Data de Publicação
2014-12-01
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • ADAME, A., e ROCHA, F. R. P. A multi-pumping flow system for acute toxicity bioassay using the Vibrio fischeri bacteria [doi:10.1039/c4ay00789a]. Analytical Methods [online], 2014, vol. 6, p. 7367-7373.
  • ADAME, A., e ROCHA, F. R. P. A multicommuted flow-based system for acute toxicity bioassay using Vibrio fischeri bacteria. In 18th International Conference on flow Analysis, Porto-Portugal, 2013. 18th International Conference on flow Analysis., 2013. Resumo.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.