• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.64.2015.tde-06102015-103803
Document
Author
Full name
Marcia Otto Barrientos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2015
Supervisor
Committee
Rocha, Fabio Rodrigo Piovezani (President)
Reis, Boaventura Freire dos
Raimundo Junior, Ivo Milton
Title in Portuguese
Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial
Keywords in Portuguese
Ácido salicílico,Clean-up em linha
Cromatografia por injeção sequencial
Extração em fase sólida
Fluorescência
Materiais vegetais
Soja
Abstract in Portuguese
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo
Title in English
Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography
Keywords in English
Fluorescence
On-line clean-up
Salicylic acid
Sequential injection chromatography
Solid-phase extraction
Soybean
Vegetable materials
Abstract in English
Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-10-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.