Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.64.2011.tde-26012012-162013
Document
Auteur
Nom complet
Gabriel Gustinelli Arantes de Carvalho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2011
Directeur
Jury
Krug, Francisco Jose (Président)
Nobrega, Joaquim de Araujo
Pasquini, Celio
Titre en portugais
Efeito da fluência na análise de pastilhas de materiais vegetais por espectrometria de emissão óptica com plasma induzido por laser
Mots-clés en portugais
Análise direta de plantas
Diâmetro de focalização do laser
Espectrometria de emissão óptica
Fluência
LIBS
Plasma induzido por laser
Resumé en portugais
A espectrometria de emissão óptica com plasma induzido por laser (LIBS) constitui um método alternativo para a determinação simultânea de macro e micronutrientes em pastilhas de materiais vegetais. No entanto, pouca informação com relação às condições de fluência e de focalização do laser mais apropriadas para a análise de pastilhas de materiais vegetais são disponíveis na literatura. O objetivo deste trabalho foi avaliar os efeitos da fluência, do diâmetro de focalização do laser e do tamanho das partículas das amostras nas análises de pastilhas de tecidos vegetais por LIBS. O arranjo experimental foi composto por um laser pulsado de Nd:YAG a 1064 nm (pulsos de 5 n'delta', 360 mJ, 10 Hz) e os sinais de emissão foram coletados por um telescópio acoplado por fibra óptica ao espectrômetro Echelle com detector ICCD. Os parâmetros instrumentais foram ajustados em 20 pulsos acumulados, 2,0 'mü's de atraso e 5,0 'mü's de integração. Amostras laboratoriais consistiram de pastilhas preparadas com folhas moídas criogenicamente (90 % das partículas < 50 'mü'm). Maiores intensidades das linhas Ca I 442,554, Mg I 277,983, P I 213,618, Al I 309,271, B I 249,773, Cu I 324,755, Fe II 261,187, Mn II 257,610 e Zn II 206,200 nm foram obtidas com fluências entre 35 e 60 J cm-2 e diâmetros de focalização entre 600 e 1050 'mü'm. O uso de fluências e diâmetros de focalização maiores concorreu para melhorar os coeficientes de variação (CV) das medidas. Fixando-se o diâmetro de focalização em 750 'mü'm, observou-se que, para a maioria dos analíticos, o CV das medidas foi reduzido 2 vezes quando a fluência foi alterada de 20 para 50 J cm-2. Nestas condições, estes resultados foram atribuídos à maior massa removida e, conseqüentemente, à amostragem mais representativa. Os coeficientes angulares das curvas de calibração também aumentaram quando a fluência foi acrescida. No entanto, não foram verificadas diferenças significativas nos coeficientes de correlação das curvas de calibração e nos limites de detecção empregando-se 25 e 50 J cm-2. Embora as intensidades dos sinais de emissão aumentem com a fluência, a emissão de fundo também aumenta. Por outro lado, o tamanho das partículas das amostras afeta as eficiências de atomização e excitação no plasma induzido por laser. Quando partículas maiores são parcialmente vaporizadas, os sinais de emissão resultantes dos processos de atomização e excitação das espécies constituintes são menores do que os provenientes de partículas menores. Nesta dissertação, melhorias significativas da intensidade dos sinais de emissão e dos CVs das medidas foram observados quando pastilhas preparadas com partículas < 75 'mü'm foram analisadas. Não foram observadas diferenças significativas nas intensidades dos sinais de emissão e no CV das medidas nas análises de pastilhas preparadas com partículas entre 20 e 75 'mü'm. Pastilhas preparadas com partículas > 75 'mü'm apresentaram problemas de coesão e, após ablação, apresentaram crateras não uniformes. A análise destas pastilhas resultou em CV das medidas geralmente > 15 %. Os resultados obtidos neste trabalho confirmaram que é recomendável utilizar amostras de calibração e amostras-teste com distribuição do tamanho das partículas semelhante para evitar efeitos físicos de matriz, que alteram as interações laser-amostra
Titre en anglais
Effect of fluence on laser induced breakdown spectrometry analysis of pellets of plant materials
Mots-clés en anglais
Direct analysis of plant materials
Fluence
Laser focusing
Laser induced breakdown spectrometry
LIBS
Resumé en anglais
Most recently, it was demonstrated that laser induced breakdown spectrometry (LIBS) constitutes an alternative for the simultaneous determination of macro- and micronutrients in pellets of plant materials. However, there is no information regarding the most appropriate fluence and laser focusing for analysis of pellets of plant materials. The aim of this work was to evaluate the effect of laser focusing and fluence on LIBS analysis of plants. The effect of particle size on LIBS analysis of pellets of plant materials as well as sample preparation approaches were also discussed. The experimental setup was designed by using a Q-switch Nd:YAG laser (5 n'delta', 360 mJ, 10 Hz, _ 'lâmbda' = 1064 nm) and the emission signals were collected by lenses into an optical fiber coupled to an echelle spectrometer equipped with a high-resolution ICCD. Instrumental parameters consisted of 20 accumulated laser pulses, 2.0 'mü's delay time and 5.0 'mü's integration time gate. Pellets prepared from cryogenically ground plant leaves (90 % particles < 50 'mü'm; median = 10 'mü'm) were used as laboratory samples and 6 laser spot diameters (from 180 to 1050 'mü'm) at different laser fluences were evaluated. Results indicate that elements emission intensities increased with both laser fluence and spot diameter. Higher intensities for Ca I 442.554, Mg I 277.983, P I 213.618, Al I 309.271, B I 249.773, Cu I 324.755, Fe II 261.187, Mn II 257.610, and Zn II 206.200 nm emission lines were observed with fluences in the 35 - 60 J cm-2 range and spot diameters between 600 and 1050 'mü'm. Higher spot diameters improved mass removal and minimized repeatability drawbacks. It was observed that the coefficients of variation (CV) of site-to-site measurements decreased by using higher laser focusing diameters. By fixing the laser spot diameter at 750 'mü'm, the CV of measurements improved at least 2-fold for all analytes when 50 J cm-2 was applied in comparison to 20 J cm-2. These results can be attributed to a larger mass removal obtained at higher laser fluences and better laser sampling representativeness. Sensitivity did also increase with laser fluence but no significant differences were observed in the detection limits using 25 and 50 J cm-2. Although emission intensities increased with laser fluence the background emission and noise increased as well. On the other hand, particle size distribution of powdered samples affects the atomization and excitation efficiencies by laser induced plasmas. When larger particles are incompletely vaporized the resulting emission signals were lower than those obtained from smaller particles. In this work, significant improvements on emission intensities and CV of measurements were observed when pellets made with particles < 75 'mü'm were analyzed. No significant differences were observed (emission intensities and CV of measurements) in the analysis of pellets prepared with particles in the 20-75 'mü'm range. Pellets prepared with particles > 75 'mü'm presented cohesion drawbacks and resulted non uniform craters after laser ablation. The CV of measurements for most analytes in these materials was > 15 %. Therefore, similar particle size distribution between calibration and test samples is recommended to avoid physical matrix effects on laser-sample interaction
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Mestrado.pdf (34.30 Mbytes)
Date de Publication
2012-01-31
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.