Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2010.tde-03052010-151533
Document
Author
Full name
Bruna Cláudia Lourenção
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2010
Supervisor
Committee
Fatibello Filho, Orlando (President)
Cavalheiro, Eder Tadeu Gomes
Codognoto, Lúcia
Title in Portuguese
Determinação voltamétrica simultânea de paracetamol e cafeína e de ácido ascórbico e cafeína em formulações famacêuticas empregando um eletrodo de diamante dopado com boro
Keywords in Portuguese
Ácido ascórbico
Cafeína
Eletrodo de diamante dopado com boro
Paracetamol
Abstract in Portuguese
Neste trabalho descreve-se o desenvolvimento de procedimentos eletroanalíticos para a determinação de paracetamol, ácido ascórbico (AA) e cafeína em formulações farmacêuticas utilizando um eletrodo de diamante dopado com boro (BDD) e voltametria de pulso diferencial (DPV). Inicialmente, foram obtidos os voltamogramas cíclicos para o paracetamol, AA e cafeína separadamente sendo os potenciais de pico anódicos de oxidação de cada um destes analitos iguais a 0,80 V, 0,92 V e 1,47 V, respectivamente. O efeito do pré-tratamento eletroquímico do eletrodo de BDD nas medidas voltamétricas foi também objeto de estudo. Os parâmetros da voltametria de onda quadrada e voltametria de pulso diferencial também foram estudados e otimizados para cada analito. No primeiro procedimento desenvolvido, determinou-se simultaneamente paracetamol e cafeína em formulações farmacêuticas utilizando o eletrodo de BDD e voltametria de pulso diferencial após a otimização das condições experimentais. A curva analítica foi linear no intervalo de concentração de paracetamol e cafeína de 5,0 × 10-7 mol L-1 a 8,3 × 10-5 mol L-1 com limite de detecção iguail a 4,9 × 10-7 mol L-1 para paracetamol e 3,5 × 10-8 mol L-1 para cafeína. O desvio padrão relativo do paracetamol e da cafeína para a repetibilidade intra-dias foi de 0,7 % e 0,2% respectivamente e para a repetibilidade inter-dias foi de 5,1% e 1,4% respectivamente. A quantificação de paracetamol e cafeína em formulações farmacêuticas utilizando um eletrodo de BDD apresentaram resultados concordantes com os resultados obtidos empregando-se um método cromatográfico em um nível de confiança de 95%. Na seqüência, um segundo procedimento foi desenvolvido para a determinação simultânea de AA e cafeína em formulações farmacêuticas utilizando o eletrodo de BDD e voltametria de pulso diferencial, após a otimização das condições experimentais. A curva analítica foi linear num intervalo de concentração de 5,0 × 10-6 mol L-1 a 1,9× 10-4 mol L-1 para AA e de 2,0 × 10-6 mol L-1 a 1,1 × 10-4 mol L-1 para cafeína com limites de detecção de 2,6 × 10-7 mol L-1 para AA e 2,4 × 10-8 mol L-1 para cafeína. O desvio padrão relativo do AA e da cafeína para a repetibilidade intra-dias foi de 0,5% e 0,2% respectivamente e para a repetibilidade inter-dias foi de 5,9% e 8,7% respectivamente. A quantificação de AA e cafeína em formulações farmacêuticas utilizando um eletrodo de BDD apresentaram resultados concordantes com os resultados obtidos empregando-se um método cromatográfico em um nível de confiança de 95%.
Title in English
Simultaneous voltammetric determination of paracetamol and caffeine and ascorbic acid and caffeine in pharmaceutical formulations using a boron doped diamond electrode
Keywords in English
Ascorbic acid
Boron doped diamond eletrodo
Caffeine
Paracetamol
Abstract in English
In this study the development of eletroanalytical procedures for paracetamol, ascorbic acid (AA) and caffeine in pharmaceutical formulations using a boron doped diamond (BDD) and differential pulse voltammetry (DPV) is described. Initially, the cyclic voltammograms of paracetamol, AA and caffeine were separately obtained with the potentials of anodic peaks of oxidation of each one of these analytes equals to 0.80 V, 0.92 V and 1.47 V, respectively. The effect of electrochemical pre-treatment of the BDD electrode in voltammetric measurements was the purpose of this study, as well. The parameters of square wave voltammetry and differential pulse voltammetry were also studied and optimized for each analyte. In the first developed procedure, it was determined both paracetamol and caffeine in pharmaceutical formulations using the BDD electrode and differential pulse voltammetry after optimization of experimental conditions. The analytical curves were linear in the paracetamol and caffeine concentration intervals, ranging from 5.0 x 10-7 mol L-1 to 8.3 x 10-5 mol L-1 with detection limit equal to 4.9 x 10-7 mol L-1 for paracetamol and 3.5 x 10-8 mol L-1 for caffeine. The relative standard deviation of paracetamol and caffeine for the intra-day repeatability was 0.7% and 0.2% respectively, and the inter-day repeatability was 5.1% and 1.4% respectively. The quantification of paracetamol and caffeine in pharmaceutical formulations using a BDD electrode showed results in agreement with those results obtained using a chromatographic method at a 95% confidence level. Subsequently, a second procedure was developed for the simultaneous determination of AA and caffeine in pharmaceutical formulations using the BDD electrode and differential pulse voltammetry, after optimization of experimental conditions. The analytical curves were linear in the concentrations ranging from 5.0 x 10-6 mol L-1 to 1.9 x 10-4 mol L-1 for AA and 2.0 x 10-6 mol L-1 to 1.0 x 10-4 mol L-1 for caffeine with detection limits of 2.6 x 10-7 mol L-1 for AA and 2.4 x 10-8 mol L-1 for caffeine. The relative standard deviation of AA and caffeine for the intra-day repeatability was 0.5% and 0.2% respectively, and the inter-day repeatability was 5.9% and 8.7% respectively. Quantification of AA and caffeine in pharmaceutical formulations using a BDD electrode showed results in accordance with the results obtained using a chromatographic method at a 95% confidence level.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.