• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2008.tde-13102008-162657
Document
Author
Full name
Fernanda Ramos de Andrade
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2008
Supervisor
Committee
Vaz, Carlos Manoel Pedro (President)
Mazo, Luiz Henrique
Souza, Djenaine de
Title in Portuguese
Determinação eletroanalítica dos herbicidas 2,4-D e metribuzin em amostras de solo utilizando um eletrodo compósito de grafite-poliuretana
Keywords in Portuguese
2.4-D
determinação eletroanalítica
eletrodo compósito de grafite-poliuretana
metribuzin
solo
voltametria de onda quadrada
Abstract in Portuguese
O presente trabalho apresenta um estudo eletroquímico da redução dos herbicidas 2,4-D e metribuzin bem como o desenvolvimento de metodologias analíticas para determinação destes compostos em amostras naturais. Os experimentos foram realizados sobre eletrodo compósito de grafite-poliuretana (GPU) utilizando a técnica de voltametria de onda quadrada (SWV). A técnica de Voltametria Cíclica (VC) foi utilizada para diagnosticar o grau de reversibilidade da reação de redução dos herbicidas assim como a natureza do transporte da material eletroativo para a superfície do eletrodo de GPU. Os eletrólitos suportes utilizados nos experimentos foram: tampão Britton-Robinson (BR) para o 2,4-D e água acidificada com H2SO4 0,1 mol L-1 para o metribuzin, ambos em pH 2. Os resultados indicaram que tanto o 2,4-D quanto para o metribuzin, apresentam um único pico de redução com características de processo irreversível controlado pela adsorção de reagente na superfície do eletrodo. Os parâmetros da técnica de SWV (freqüência, amplitude e incremento de varredura), bem como o tempo e potencial de acumulação foram otimizados para obtenção de maior sensibilidade analítica. Curvas analíticas dos dois herbicidas foram obtidas no intervalo de 1,5 a 12 µmol L-1 para os dois herbicidas. Os limites de detecção (LD) e de quantificação (LQ) obtidos para o 2,4-D, foram de 17,6 µg L-1 e 58,6 µg L-1, respectivamente. Para o metribuzin, o LD foi de 1,67 µg L-1 e o LQ 5,56 µg L-1. A precisão das metodologias desenvolvidas foi avaliada por meio da repetibilidade e a reprodutibilidade e a exatidão determinada pelo erro relativo. Os testes de recuperação realizados pelo método de adição de padrão forneceram valores de 104 % para o 2,4-D e 102 % para o metribuzin. As metodologias eletroanalíticas desenvolvidas para determinação do 2,4-D e do metribuzin, foram aplicadas em um estudo para avaliação do tempo de percolação dos mesmos em dois solos com características distintas. Os resultados indicaram que os dois herbicidas apresentam alta mobilidade nos solos estudados, pois 24 horas após a aplicação já foi possível detectar a presença dos mesmos na solução do solo extraída. Para o 2,4-D, 7 dias após o início do experimento, foram encontrados apenas resíduos de herbicida, enquanto que para o metribuzin obteve-se concentrações próximas a 1 mg L-1, mesmo depois de 14 dias. Após 100 dias do início do experimento observou-se um maior acúmulo de 2,4-D no solo arenoso, que pode ter ocorrido devido ao teor mais elevado de MO do solo argiloso, que proporciona uma quantidade maior de microorganismos no solo e que podem degradar o 2,4-D. Já para o metribuzin pode-se observar que este fica adsorvido nas primeiras profundidades do solo argiloso, possivelmente pelas maiores quantidades de MO e CTC. O eletrodo de GPU com a técnica de SWV apresentou bons resultados no que diz respeito à sensibilidade e ao tempo de análise, sendo uma excelente alternativa ao eletrodo de mercúrio, usualmente utilizado em medidas eletroanalíticas do 2,4-D e metribuzin. Os resultados obtidos com amostras de solo e formulação comercial dos herbicidas são bastante coerentes, considerando a dinâmica da dissipação espacial e temporal dos herbicidas no perfil do solo.
Title in English
Electroanalytical determination of the herbicides 2,4-D and metribuzin in soil samples using graphite-polyurethane composite electrode.
Keywords in English
2.4-D
electroanalytical determination
graphite-polyurethane composite electrode
metribuzin
soil
square wave voltammetry
Abstract in English
This research presents an electrochemical study of the herbicides 2,4-D and metribuzin reductions and the development of analytical methodologies for the determination of such substances in natural samples. The experiments were done with a graphite-polyurethane composite electrode (GPU) using the square wave voltammetry (SWV). The cyclic voltammetry (CV) was used to evaluate the reversibility degree of the herbicides reductions and thus the transport nature of the electroactive material to the surface of the GPU electrode. The supporting electrolytes used in the experiments were Britton-Robinson (BR) buffer for the 2,4-D and acidified water with H2SO4 0,1 mol L-1 for the metribuzin, both at pH 2. Results indicated that the 2,4-D and metribuzin show one reduction peak reduction with irreversible process characteristics, which are controlled by the adsorption of the reagent in the electrode surface. The SWV technique parameters (frequency, amplitude and scanning increment) and the time and potential of accumulation were optimized in order to obtain the highest analytic sensibility. Analytical curves were obtained from 0,33 mg L-1 to 2,62 mg L-1 for 2,4-D and 0,32 mg L-1 to 4,72 mg L-1 for metribuzin. The detection (LD) and quantification limits (LQ) obtained for 2,4-D were 17,6 µg L-1 and 58,6 µg L-1, respectively. For metribuzin, the LD was 1,67 µg L-1 and the LQ was 5,56 µg L-1. The precision of the developed methodologies was evaluated though its repeatability and reproductibility, besides the accuracy were determined by the relative error. Recovery experiments done by the standard addition method, provided values of 104 % for the 2,4-D and 102 % for the metribuzin. The electroanalytical methodologies developed for the determination of these herbicides were applied in two different soils with distinct characteristics, one sandy and other clayed soil. Results indicate that the herbicides present high mobility in the studied soils and 24 hours after its application it was possible to detect the presence of the herbicides in the soil solution extract. For the 2,4- D, seven days after the beginning of the experiment it was measured only residues, but for the metribuzin it is possible to measure concentrations around 1 mg L-1, even after fourteen days. After 100 days it was observed the highest accumulation of the 2,4-D in the sandy soil, that can be explained by the highest content of OM in the clay soil, which provides a higher content of 2,4-D degrading microorganisms. The herbicide metribuzin was adsorbed in the first layers of the clay soil, possibly due to the higher CTC and OM amounts in the soil profile. The GPU electrode with the SWV technique presented very good results when considered the sensibility and time analyses, being an excellent alternative for the mercury electrode usually used in the electroanalytical measurements of the 2,4-D and metribuzin. The obtained results with soil samples and commercial formulation of the herbicides are very consistent, considering the spatial and temporal dissipation dynamics of the herbicides in the soil.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2008-10-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.