• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2012.tde-17042012-115050
Document
Author
Full name
Gustavo Henrique Lourenço Vicente
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2011
Supervisor
Committee
Vieira, Eny Maria (President)
Brondi, Silvia Helena Govoni
Sanches, Sergio Marcos
Title in Portuguese
Desenvolvimento e validação de um método analítico para determinação dos fármacos Diclofenaco, Nimesulida e Paracetamol em águas superficiais da cidade de São Carlos-SP
Keywords in Portuguese
diclofenaco
fármacos
HPLC
nimesulida
paracetamol
SPE
Abstract in Portuguese
Residuos de fármacos estão presentes em diversas matrizes ambientais e estudos focados na determinação destes tem ganhado grande importância nos últimos anos, devido ao aumento do consumo de medicamentos pela população. A questão do controle de resíduos de compostos farmacologicamente ativos no meio ambiente aquático foi reconhecida como uma das questões emergentes na Química Ambiental, e tem-se dado maior importância visto que os fármacos são encontrados em matrizes em estudos em concentrações de μgL-1 e ngL-1. Nesta pesquisa estudou-se três fármacos antiflamatórios que são amplamente consumidos pela população: diclofenaco, nimesulida e paracetamol. O método analítico foi desenvolvido e validado para a determinação destes fármacos em amostras de águas superficiais da cidade de São Carlos (SP). Inicialmente foi feita a validação do método proposto segundo a Resolução DOQ-CGCRE-008 do INMETRO. Os limites de detecção, e de quantificação e inferior de quantificação do método para a determinação do diclofenaco, nimesulida e paracetamol, foram, respectivamente, 0,5; 1,1 e 1,1 μgL-1. A linearidade, desvio-padrão relativo, exatidão e recuperação média para o diclofenaco foram, respectivamente, R de 0,99, 3,03%, 100,55% e 97,94%. Para a nimesulida, os valores de linearidade, desvio-padrão relativo, exatidão e recuperação, foram, R de 0,98, 2,43%, 101,46% e 100,67%. Já para o paracetamol obteve-se os seguintes valores para linearidade, desvio-padrão relativo, exatidão e recuperação, R de 0,99, 3,50%, 97,94% e 93,17%, respectivamente. Na segunda etapa deste estudo aplicou-se o método validado na análise de amostras de águas coletadas na cidade de São Carlos (SP). Para o método de extração utilizou-se a extração em fase sólida (SPE) e como técnica analítica utilizou-se o HPLC/DAD. Os resultados não indicaram a presença dos fármacos diclofenaco, nimesulida e paracetamol até o limite de detecção do método empregado.
Title in English
Development and validation of analytical method for determining the drug diclofenac, nimesulide and acetaminophen in surface waters from São Carlos
Keywords in English
acetaminophen
diclofenac
drugs
HPLC
nimesulide
SPE
Abstract in English
Residues of drugs are present in various environmental matrices and studies focused on the determination of these have gained in importance in recent years, due to increased drug consumption by the population. The issue of control of residues of pharmacologically active compounds in the aquatic environment was recognized as one of the emerging issues in environmental chemistry, and has given greater importance since the drugs are found in studies in matrices at concentrations μgL-1 and ngL-1. In this study was studied three drugs that are widely consumed by the population: diclofenac, nimesulide and acetaminophen. The analytical method was developed for the determination of these drugs in surface water samples from São Carlos (SP). Initially, made a validation of the method proposed second resolution DOQ-008-CGCRE INMETRO. The detection, quantification and lower quantification limits of method for determining of diclofenac, nimesulide and paracetamol were 0.5, 1.1 and 1.1 μgL-1, respectively. The linearity, relative standard , accuracy and average recovery of the method for diclofenac were, respectively, R equal to 0.99, 3.03%, 100.55% and 97.94%. For nimesulide, the values of linearity, relative standard, accuracy and recovery were R equal to 0.98, and 2.43%, 101.46% and 100.67%. For acetaminophen obtained the following values for linearity, relative standard, accuracy and recovery, R equal to 0.99, 3.50%, 97.94% and 93.17% respectively. In the second stage of the study applied the validated method in the analysis of water samples collected in the São Carlos (SP). For extracting the drugs, SPE cartridges were used followed by HPLC / DAD. The results indicate the absense of the studied drugs diclofenac, nimesulide and acetaminophen down to the detection limits of the method employed.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-07-31
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.