Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2008.tde-18042008-102139
Document
Author
Full name
Osmair Benedito da Silva
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2008
Supervisor
Committee
Machado, Sergio Antonio Spinola (President)
Consolin Filho, Nelson
Souza, Djenaine de
Title in Portuguese
Estudo estatístico do desempenho analítico das técnicas eletroquímicas VPD, VOQ e MVOQ para a redução do herbicida paraquat em UME-Au e sua quantificação em águas puras e naturais
Keywords in Portuguese
águas naturais
estatística
paraquat
técnicas eletroquímicas
Abstract in Portuguese
Neste trabalho foi realizado um estudo estatístico do desempenho analítico das técnicas eletroquímicas Voltametria de pulso diferencial (VPD), Voltametria de onda quadrada (VOQ) e Voltametria de múltiplas ondas quadradas (VMOQ) para a redução do herbicida paraquat em ultramicroeletrodo de ouro (UME-Au) e sua análise e quantificação em águas puras e naturais. Os estudos da redução eletroquímica do paraquat foram realizados em eletrólito de suporte Na2SO4 0,1 mol L-1 em pH = 5,5. Os resultados mostraram a presença de dois picos de redução bem definidos , com o pico 1 em -0,64 V e o pico 2 em -0,94 V vs Ag/AgCl 3,0 mol L-1. Para as análises foi utilizado o pico 1 que é referente a uma reação em solução, onde a superfície eletródica serve apenas como intermediadora na transferência eletrônica. Utilizando-se os parâmetros experimentais e voltamétricos otimizados, curvas de trabalho foram construídas em eletrólito de suporte preparado com água ultrapurificada. Para a VPD, VOQ e VMOQ, os limites de detecção encontrados utilizando-se o método descrito em Miller & Miller e considerando-se o pico 1 foram: 55,35 ± 0,18 µg L-1 , 37,50 ± 0,32 µg L-1 e 21,42 ± 0,51 µg L-1, respectivamente. A metodologia foi aplicada em amostras de águas coletadas no Rio Mogi-Guaçu na cidade de São Carlos-SP. A variação da inclinação das curvas de trabalho obtida nas análises destas amostras foi praticamente insignificante em relação àquela obtida utilizando-se o eletrólito de suporte preparado com água ultrapurificada para as três técnicas utilizadas, mostrando pouca interferência da matéria orgânica presente nas amostras de águas naturais. Os menores valores de concentração mensuráveis de paraquat nas amostras de águas naturais foram inferiores ao valor máximo de resíduos permitido pela legislação brasileira para águas residuárias (100 µg L-1), mostrando a viabilidade na aplicação da metodologia proposta. Os cálculos dos limites de detecção e quantificação, a avaliação dos erros experimentais e os limites de confiança foram realizados a partir do procedimento estatístico descrito em Miller & Miller. Os valores de limites de detecção encontrados apresentam um significado físico e realístico para esta grandeza, já que foram determinados por interpolação nas curvas analíticas, construídas a partir da relação entre as concentrações do pesticida e os sinais obtidos. Estes mesmos limites foram calculados utilizando-se o método recomendado pela IUPAC e os valores encontrados foram 29,43 µg L-1 para VPD, 3,63 µg L-1 para VOQ e 0,37 µg L-1 para VMOQ. Estes resultados mostram diferenças de até 2 ordens de grandeza de uma técnica para outra, que se não forem bem avaliados podem levar o analista a conclusões equivocadas.
Title in English
Statistic study of the analytical performance of DPV, SWV and MSWV electrochemical techniques for the reduction of the paraquat herbicide on an Au-UME and its analysis and quantification in pure and natural waters
Keywords in English
electrochemical techniques
natural waters
paraquat
statistic
Abstract in English
Statisctic studies of the analytical performance of Differential pulse voltammetry (DPV), Square wave voltammetry (SWV) and Multiple square wave voltammetry (MSWV) electrochemical techniques was performed for the electrochemical reduction of the paraquat herbicide on an gold ultramicroelectrode (Au-UME), aiming its analysis and quantification in pure and natural waters. The electrochemical reduction of paraquat was studied in 0.1 mol L-1 Na2SO4 support electrolyte in pH = 5.5 . The electrochemical responses showed two well-defined reduction peaks with potentials of -0.64 and -0.94 V vs Ag/AgCl 3.0 mol L-1 for peaks 1 and 2, respectively. The mathematical treatment was performed with data from peak 1, which is associated with a reversible solution reaction, where the electrode surface acts only as the electron transfer mediator. Working curves were obtained using the optimized experimental parameters in support electrolyte prepared with high purity water. To DPV, SWV and MSWV, the detection limits found for the peak currents associated to peak 1 were: 55.35 ± 0.18 µg L-1, 37.50 ± 0.32 µg L-1 and 21.42 ± 0.51 µg L-1, respectively. An analogous analytical procedure was applied in water samples collected in Mogi-Guaçu River, in São Carlos County, state of São Paulo. The variation in slope values, between curves obtained from pure water and those from river waters were practically depreciable for the three analytical methods, showing that the organic components and others contaminants present in natural waters caused only a minor interference in the measurements. The lower measurable values for paraquat in water samples were smaller than the allowed maximum of residue established by the Brazilian legislation for waste waters (100 µg L-1), indicating the developed methodology as convenient to such application. Calculations of detection and quantification limits, the evaluation of experimental errors and the limits of confidence were performed by the statistical procedure reported by Miller & Miller. The obtained detection limits values present a true physical significance, in a realistic order of magnitude, as they were determined by interpolation of the experimental analytical curves. The same analytical curves were submitted to the IUPAC methodology yielding the values of 29.43, 3.63 and 0.37 µg L-1 para DPV, SWV and MSWV, respectively, for pure water measurements. These results showed a difference up to two orders of magnitude from those obtained by the statistical methodology and may promote false conclusions, if not properly evaluated.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2008-04-22
 
WARNING: Learn what derived works are clicking here.