• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2016.tde-26042016-140737
Documento
Autor
Nombre completo
Mariane Aissa Andrade
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2016
Director
Tribunal
Lanças, Fernando Mauro (Presidente)
Cardoso, Daniel Rodrigues
Oliveira, Anderson Rodrigo Moraes de
Título en portugués
Determinação de ocratoxina A em vinho utilizando microextração em fase sólida no tubo e cromatografia líquida de alta eficiência com detecção por espectrometria de massas sequencial
Palabras clave en portugués
HPLC-MS/MS
microextração em fase sólida no tubo
Ocratoxina A
vinho
Resumen en portugués

As micotoxinas são compostos produzidos por fungos, sendo potencialmente perigosos à saúde humana e animal. A Ocratoxina A (OTA) é uma das micotoxinas mais amplamente estudadas, sendo encontrada em várias matrizes alimentícias. A concentração dessa micotoxina nos alimentos é geralmente muito baixa (da ordem de ng g-1), sendo, portanto, necessário o emprego de técnicas de preparo de amostras que realizem a purificação e pré-concentração no analito. Os métodos de separação e detecção empregados na análise de OTA também devem oferecer sensibilidade adequada para a quantificação do analito. Logo, os objetivos do trabalho foram desenvolver uma metodologia utilizando a técnica in-tube SPME no modo de extração única (flow through extraction) com partículas de C18 como fase extratora e separação e detecção por HPLC-MS/MS. Além disso, otimizar e validar a metodologia proposta e detectar e quantificar a OTA em amostras de vinho. Para isso, a técnica in-tube SPME foi configurada e um tubo de PEEK foi empacotado com partículas de C18, o qual foi utilizado na extração. A otimização do método foi realizada utilizando-se um planejamento experimental composto central 22 + 3 pontos centrais, tendo como fatores a porcentagem de ACN e o tempo durante o carregamento da amostra. A validação da metodologia empregada foi realizada conforme o guia de validação da ANVISA e, posteriormente, amostras de vinho tinto seco e vinho branco seco foram analisadas. O método proposto foi desenvolvido, tendo sua funcionalidade atestada e suas condições de análise melhoradas, sendo utilizado 22 % de ACN e 6 minutos no carregamento da amostra. O método foi validado, mostrando sensibilidade adequada, com limites de detecção e quantificação iguais à 0,02 e 0,05 µg L-1, respectivamente. A linearidade e precisão da metodologia foram avaliadas, apresentando coeficiente de correlação igual a 0,996 e DPR menor que 6%, respectivamente. O método mostrou-se exato nos níveis de concentração médio e alto e a recuperação máxima obtida para o nível alto foi próximo 73%. Amostras brasileiras e estrangeiras de vinho tinto seco e vinho tinto seco branco foram analisadas e a OTA não foi detectada em nenhuma delas. Entretanto, a OTA pode essa estar presente nas amostras analisadas em concentrações mais baixas que as determinadas pelos limites de detecção e quantificação, não sendo potencialmente perigosos à saúde.

Título en inglés
Determination of ochratoxin A in wine by solid phase microextraction and high performance liquid chromatography with mass spectrometry detection
Palabras clave en inglés
HPLC-MS/MS
Ochratoxin A
solid phase microextraction
wine
Resumen en inglés

Mycotoxins are compounds produced by fungus, being a potential danger to human and animal health. Ochratoxin A (OTA) is a mycotoxin widely studied, being found in a varied of food matrices. OTA concentration in food is generally low (the order of ng g-1), being, therefore, necessary the use of sample preparation techniques to perform the analyte purification and preconcentration in the sample. The separation and detection methods used in OTA analysis also should offer proper sensibility in order to quantify the analyte adequately. In short, the goals of the present work were to develop a methodology using in-tube SPME in flow through extraction mode with C18 particles as extraction phase and separation and detection by HPLC-MS/MS. Further, optimize and validate the proposed methodology and detect and quantify OTA in wine samples. For this, in-tube SPME was configured and a PEEK tube was packed with C18 particles, which was used in the extraction step. The method optimization was achieved using a central composite 22 + 3 central points experimental design, having as factors the percentage of ACN and time during sample loading step. Validation method was done following ANVISA validation guide after which red dry wine and white dry wine samples were analyzed. The proposed method was developed, having its functionalities attested and its analysis conditions enhanced, using 22% of ACN and 6 minutes in sample loading. The method was validated, demonstrating proper sensitivity, with detection and quantification limits equal to 0.02 and 0.05 µg L-1, respectively. Linearity and precision were evaluated, exhibiting correlation coefficient equal to 0,996 e RSD under 6%, respectively. The method was accurate in medium and high concentration levels and maximum recovery was 73% in high concentration level. Brazilian and foreign red dry wine and white dry wine samples were analyzed and OTA was not detected in any of them. However, OTA may be present in samples analyzed in lower concentrations than that ones determined by detection and quantification limits, not being a potential danger to human health.

 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-04-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.