• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2013.tde-28112013-114840
Documento
Autor
Nombre completo
Scarlet Nere Ortega
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2013
Director
Tribunal
Lanças, Fernando Mauro (Presidente)
Cardoso, Daniel Rodrigues
Oliveira, Anderson Rodrigo Moraes de
Título en portugués
Análise de estatinas em plasma humano utilizando microextração por dispositivo preenchido com sorvente (MEPS) e cromatografia líquida acoplada à espectrometria de massas sequencial (LC-MS/MS)
Palabras clave en portugués
estatinas
LC-MS/MS
MEPS
plasma humano
Resumen en portugués
As elevadas taxas de colesterol plasmático representam um grande risco à saúde, uma vez que podem causar doenças cardiovasculares. Para o tratamento e prevenção da dislipidemia são utilizados medicamentos reguladores do colesterol, como as estatinas. Embora eficazes e extensamente utilizados, esses fármacos apresentam efeitos adversos se administrados na dosagem errada. Assim, faz-se necessário o desenvolvimento de um método de monitorização terapêutica a fim de se ajustar a concentração desses compostos no sangue. Este trabalho visa o desenvolvimento de um método para análise de pravastatina (PRA), atorvastatina (AT), fluvastatina (FLV) e sinvastatina (SV) em plasma humano usando cromatografia líquida acoplada à espectrometria de massas (LC-MS). Na etapa de preparo de amostras, de forma inédita, utilizou-se a técnica microextração por sorvente empacotado (MEPS) para a análise de plasma humano contendo quatro estatinas. Para a otimização das condições de extração avaliaram-se, por experimentos univariados, parâmetros como fase extratora, composição do solvente de eluição e de lavagem. Outros fatores como volume de amostra, ciclos de amostragem, ciclos de eluição e etapas de eluição foram avaliados empregando-se planejamento experimental multivariado. A extração foi realizada utilizando-se uma fase estacionária C18 Chromabond como sorvente. O método MEPS-LC-MS/MS desenvolvido foi validado baseando-se nas recomendações da agência nacional de vigilância sanitária (ANVISA) e apresentou linearidade, seletividade, precisão, exatidão e recuperação adequadas para as estatinas, excetuando-se para a sinvastatina. A faixa de linearidade obtida foi de 10-200 ng mL-1 (FLV e AT) e 20-200 ng mL-1 (PRA). Os limites de quantificação obtidos foram da ordem de 10 ng mL-1 (AT e FLV) e 20 ng mL-1 (PRA). Desta forma o método desenvolvido poderá ser utilizado para a determinação dos níveis de pravastatina, fluvastatina e atorvastatina em amostras de plasma humano.
Título en inglés
Determination of statins in human plasma using microextraction in packed syringe (MEPS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
Palabras clave en inglés
human plasma
LC-MS/MS
MEPS
statins
Resumen en inglés
Elevated plasma cholesterol level is a risk factor for coronary diseases, which are the most deadly sickness according to the World Health Organization (WHO). In order to fight the hypercholesterolemia in patients, statins are a well-established class of drugs to be prescribed. Even though they are efficient, some side effects can be associated with statin therapy, especially when interactions with other drugs occur. In these cases, monitoring the concentration can optimize the drug dosage to therapeutic effectiveness whilst minimizing the adverse effects. The aim of this work was to develop a method for analysis of pravastatin (PRA), atorvastatin (AT), fluvastatin (FLV) and simvastatin (SV) in human plasma. The experimental means chosen to attain the goal was liquid chromatography-tandem mass spectrometry (LC-MS/MS) and for the sample preparation, microextraction by packed sorbent (MEPS). To optimize the extraction conditions, parameters such as sorbent, elution and washing solution were evaluated. Other parameters such as sampling, elution cycles, sample volume and elution steps were evaluated using multivariate experimental design. The extraction was performed using C18 Chromabond as sorbent. The method was validated based on ANVISA recommendations and featured appropriated linearity, selectivity, accuracy, precision, and recovery, except for simvastatin. The calibration curve in plasma was obtained in the concentration range 10-200 ng mL-1 (FLV and AT) and 20-200 ng mL-1 (PRA) and the limit of quantification (LOQ) was 10 ng mL-1 (FLV and AT) and 20 ng mL-1 (PRA). The method developed proved to be suitable for the analysis of pravastatin, fluvastatin and atorvastatin in human plasma sample, but not simvastatin, and it can contribute to a more efficient usage of the statins in the treatment of hypercholesterolemia.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-03-12
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.