  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.76.2012.tde-05062012-162759
Document
Author
Full name
Renato Ferracini Alves
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Magalhães, Daniel Varela (President)
Courteille, Philippe Wilhelm
Garcia, Guilherme de Andrade
Title in Portuguese
Chafariz atômico de Cs 133
Keywords in Portuguese
Césio
Espectroscopia Ramsey
Metrologia
Padrão de frequência atômico
Relógio atômico
Abstract in Portuguese
Esta dissertação descreve os recentes desenvolvimentos do Chafariz Atômico localizado no Instituto de Física de São Carlos. Ele consiste de um aparato experimental que provê uma referência de freqüência (e tempo) de altíssima precisão. Para conseguir tal qualidade metrológica, esse sistema trava a freqüência de um oscilador eletrônico, baseado em um cristal de quartzo, na freqüência relativa a uma transição atômica, de uma amostra de átomos resfriados. O átomo utilizado é o 133Cs e a transição utilizada corresponde aos dois níveis hiperfínos do seu estado fundamental. O ciclo de funcionamento é composto por uma etapa de aprisionamento a laser dos átomos e bombeamento óptico, para que todos os átomos se encontrem num mesmo e determinado nível de energia. Esses átomos são então lançados opticamente contra a gravidade através de uma cavidade de microondas. Em trajetória balística e livre de interferências externas, o conjunto de átomos sofre uma possível mudança de estado, dependendo das características de potência e freqüência do sinal de microondas injetado na cavidade. Esta probabilidade de transição é o sinal de erro utilizado para travar em malha fechada o gerador de microondas que alimenta a cavidade. Os melhores resultados obtidos neste experimento foram uma estabilidade de 5x10-12τ-1/2 resultante de um sinal com 3Hz de largura a meia altura (FWHM) da franja central. Fizemos também uma avaliação preliminar dos principais deslocamentos de freqüência e uma análise de interação espacial dos átomos com o campo de microondas.
Title in English
Cs 133 Atomic Fountain
Keywords in English
Atomic clock
Atomic frequency standard
Cesium
Metrology
Ramsey spectroscopy
Abstract in English
This paper describes the recent developments of the Atomic Fountain located at the São Carlos Physics Institute. It provides a very high resolution frequency (and time) reference. This is achieved locking an electronic oscillator, based on a quartz crystal, to an atomic resonance of a cold atomic sample. Our laboratory uses the 133Cs atom, using as the referenced transition that corresponds to the two hyperfine energy levels of the ground state. The operating cycle comprises a stage of laser trapping atoms or optical pumping, so that all atoms are within the same atomic state. These atoms are then launched optically against gravity through a microwave cavity. In ballistic trajectory and free from external interference, the set of atoms undergoes a change of state, depending on the power and frequency of the microwave signal injected into the cavity. This transition probability is the error signal used to lock the microwave generator supplying the cavity in a closed loop. The best result obtained in this experiment was a stability of 5x10-12τ-1/2 resulting from signal with a 3 Hz half width (FWHM) of the central fringe. We also provide a preliminary assessment of the main frequency shifts and an analysis of spatial interaction of atoms with the microwave field.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-06-11
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.